BEFORE YOU START
1-800-343-9463
1.
Inspect all components prior to installation.
If damage
or missing components are
found, please
notify
WhisperKOOL
Customer Service at 1-800-343-9463 within 30 days.
2.
The evaporator unit
requires a dedicated 120V, 15-amp circuit
. A surge protector is recommended to use with the unit.
Do
not use a GFI outlet or breaker.
3.
The condensing unit
requires a dedicated 220V, 15-amp circuit
. A surge protector is recommended to use with the unit.
Do
not use a GFI
outlet or breaker.
4.
Communication cable (18-5 thermostat wire) must be ran between the condensing unit and the evaporator unit. Only 2 of the
communication wires will be used. For 24V
thermostat equipped
systems
an
18-5 cable must be used to connect the
thermostat to the evaporator
unit.
5.
You are
REQUIRED
to
install a drain line
to remove condensation from the evaporator unit (fan coil unit).
6.
The warranty is not active until a warranty checklist has been received, reviewed, and approved.
7.
The system is intended
for use in properly designed and constructed wine cellars.
Hire a professional wine storage
consultant with a valid contractor’s license to build your wine cellar.
8.
WhisperKOOL requires that all split systems be installed by a certified HVAC-R technician only. NATE or equivalent is
recommended.
If you encounter a problem with your WhisperKOOL system, please refer to the Troubleshooting Guide. If you have any further
questions or concerns, or need assistance, please contact WhisperKO
OL's
Customer Service at 1-800-343-9463. Please be sure
all testing has been completed prior to contacting Customer Service. Please have your results ready for your representative.
Page 3
08/04/21