Ceiling Mount 8000 Specifications
C
eiling
M
ount
8000 S
pecifications
Model
Ceiling Mount 8000 Evaporator
(Fan Coil Unit)
C
eiling
M
ount
8000
H.E.
Condenser
(Air-Cooled Condensing Unit)
Fan Speed
Medium
Dimensions
Refrigerant
R-134a
Condensing Unit
HP
0.
7
HP
Voltage Rating
1
20
V (15-amp dedicated circuit required)
Weight (lbs)
66
5
6
Amps
1.4 Running Amps
Line Set
Liquid line 1/4"
OD
; Suction line 1/2" OD (less than 50ft.),
5
/8" (greater than 50.ft)
Drain Line
1/4" ID clear plastic tubing (not provided) - Rigid tube recommended
Installation
Evaporator unit is
in
stalled in
the cellar.
Condensing unit can be installed up to 100 line feet from the evaporator unit.
Thermostat
KDT-
Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable)
, 24V - Customer supplied
Temp. Delta
Can maintain a 55°F cellar temperature with up to 1
2
0°F condenser air intake temperature
Warranty
Two-year limited warranty (parts and labor)
High
BTU/h ( 60°F condenser air intake
temperature)
Sensible/Total
BTU/h (
75
°F condenser air intake
temperature)
Sensible/Total
BTU/h (
8
5
°F condenser air intake
temperature)
Sensible/Total
5
305
/
6
264
5411
/
6411
5114
/
5498
5217
/
5615
5
064
/
5
358
5157
/
5544
H.E.
Condenser (Air-Cooled
Condensing Unit)
35.75
”L x
14.5
"W
x
12.75
”H
31.18"L x 10.75”
W
x 21.18"H
220
V (15-amp dedicated circuit required)
LRA
13.2
A, RLA
3.19
A, FLA
3.66
A
Cellar Size
2000
cu. ft.