13
*At 0.1 to 0.5 ESP
*At 0.1 to 0.5 ESP
**Denotes factory setting for WGPH4543AM
***Denotes factory setting for WGPH4549AM
*At 0.1 to 0.5 ESP
(F)
Factory setting
WGPH4530AM, WGPH4536AM
Cooling/HP
Speed
Adjust
Tap
CFM*
Electric
Heat
Adjust
Tap
CFM*
D
Minus
720
D
Minus
720
D
Normal 800
D
Normal 800
D
Plus
880
D
Plus
880
C
Minus
900
C
Minus
900
C
Normal 1,000
C
Normal 1,000
C
Plus
1,100
C
Plus
1,100
B
Minus
990
B
Minus
990
B
Normal 1,100
B
Normal 1,100
B
Plus
1,210
B
Plus
1,210
A
Minus
1,125
A
Minus
1,125
A
Normal 1,250
A
Normal 1,250
A
Plus
1,375
A
Plus
1,375
WGPH4543AM, WGPH4549AM
Cooling/HP
Speed
Adjust
Tap
CFM*
Electric
Heat
Adjust
Tap
CFM*
D
Minus
1,103
D
Minus
1,103
D
Normal 1,225
D
Normal 1,225
D
Plus***
1,348
D
Plus
1,348
C
Minus**
1,260
C
Minus**
1,260
C
Normal 1,400
C
Normal 1,400
C
Plus
1,540
C
Plus
1,540
B
Minus
1,530
B
Minus
1,530
B
Normal 1,700
B
Normal 1,700
B
Plus
1,870
B
Plus
1,870
A
Minus
1,620
A
Minus
1,620
A
Normal 1,800
A
Normal 1,800
A
Plus
1,980
A
Plus***
1,980
WGPH4560AM
Cooling/HP
Speed
Adjust
Tap
CFM*
Electric
Heat
Adjust
Tap
CFM*
D
Minus
1,260
D
Minus
1,260
D
Normal 1,400
D
Normal 1,400
D
Plus
1,540
D
Plus
1,540
C
Minus
1,440
C
Minus
1,440
C
Normal 1,600
C
Normal 1,600
C
Plus
1,760
C
Plus
1,760
B
Minus
1,620
B
Minus
1,620
B
Normal 1,800
B
Normal 1,800
B
Plus
1,980
B
Plus
1,980
A
Minus
1,800
A
Minus
1,800
A
Normal 2,000
A
Normal 2,000
A
Plus
2,200
A
Plus
2,200
CFM Output for DIP Switch Combinations 1 and 2—
Electric Heat
Model
Speed
Tap
Switch 1 Switch 2
Electric
Heat—CFM
WGPH4524
A
Off
Off
1,050
(F)
B
1,400
Off
950
C
Off
On
825
D
On
On
700
WGPH4530
A
Off
Off
1,250
(F)
B
On
Off
1,100
C
Off
On
1,000
D
On
On
800
WGPH4536
A
Off
Off
1,250
(F)
B
On
Off
1,100
C
Off
On
1,000
D
On
On
800
WGPH4543
A
Off
Off
1,800
B
On
Off
1,700
C
Off
On
1,400
(F)
D
On
On
1,225
WGPH4549
A
Off
Off
1,800
B
On
Off
1,700
C
Off
On
1,400
D
On
On
1,225
(F)
WGPH4560
A
Off
Off
2,000
(F)
B
On
Off
1,800
C
Off
On
1,600
D
On
On
1,400