COMPONENT ACCESS
Whirlpool Compact Heat Pump Dryer
n
4-19
Removing the Front Bulkhead
To Remove the Front Bulkhead
1. Unplug dryer or disconnect power.
2. Perform the procedure on page 4-9, “Remove the Top
Panel” prior to performing the following steps.
3. Perform the procedure on page 4-9, “Remove the Side
Panels” prior to performing the following steps.
4. Perform the procedure on page 4-11, “Remove the
Console/User Interface” prior to performing the following
steps.
5. Perform the procedure on page 4-13, “Remove the Water
Tank” prior to performing the following steps.
6. Perform the procedure on page 4-17, “Remove the Front
Panel” prior to performing the following steps.
7. Perform the procedure on page 4-18, “Remove the Drum”
prior to performing the following steps.
8. Disconnect the moisture sensor harness.
9. Remove the main harness run from the front of the
bulkhead. The harness is secured to the bulkhead by one
clip and 2 or 3 guides. See Figure 2 in the next column.
10. Remove the two 7 mm screws securing the front bulkhead
to the base assembly (see Figure 1 below).
11. Locate the right and left-side clips securing the front
bulkhead to the base assembly (see inset in Figure 2.) Lift
up and remove the front bulkhead assembly from the
base.
Remove
Screw
Remove
Screw
Figure 1
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
Main
Harness
Guides
Main
Harness
Guide
Main
Harness
Clip
Figure 2
R & L
Bulkhead
Clips