31
Pro Series
Furnace Operations Manual
SELECT PROGRAM
99 MAN – ADD TEMP
Figure 44
FINAL TEMP
XXXC
Figure 45
HOLD TIME
Figure 46
COOL TIME
0:00
Figure 47
Running a Manual Glazing Program
The
Pro Series
furnaces allow users to quickly create a
glazing program.
Procedure:
1. Press the
Run Program
button.
2. Turn the
Select Knob
to program number 99. Program
number 99 is the Manual Add Temperature Program.
3. Press the
Start Program
button to begin.
4. The display will read as shown below. Turn the
Select
Knob
to the final temperature for this program.
5. The
HOLD TIME will be displayed as shown below.
Turn the
Select Knob
to select the time you wish
to hold the porcelain at the final temperature.
6. Press the
Next
button to continue.
7.
COOL TIME will be displayed. Turn the
Select Knob
to
the desired cool time. This is the time the furnace uses
to bring the table to its fully down position. The table will
be lowered in steps evenly spaced during the cool time.
8. Press the
Next
button. The table will rise and the
program will run. All of the normal displays are
available while running a manual program.
15946 Pro Series English.indd 31