17
Pro Series
Furnace Operations Manual
Testing Your Furnace
The
Pro 100
and
Pro Press 100
are capable of
performing several tests to aid in diagnosing the furnace
should a problem occur. A technician may ask you to
run one or more of these tests to aid in diagnosing the
problem. The tests include a vacuum test, a muffle test,
a motor up test, a motor down test, and a muffle hour
reading. The muffle hour reading is incremented by 1 for
each hour the muffle temperature is above
651°
C
.
1. Press the
Special Functions
button.
2. Turn the
Select Knob
until the display reads
TEST FURNACE.
3. Press the
Next
button.
4. Turn the
Select Knob
until the test you require
is displayed.
5. Press the
Next
button. The test that was selected
will now begin.
6. Pressing the
Next
button will stop or pause the test.
Pressing the
Next
button again will restart or stop
the test.
7. Pressing any of the Menu buttons to the left of the
Select Knob
will end the test.
Note:
The muffle test is used by technical support
and engineering for troubleshooting muffle problems.
The number on the left of the display is the current
room temperature. The number in the middle is the
thermocouple output. The number to the right indicates
the current lift position (99 = up or down/0 = moving or
between top and bottom).
Calibrate Oven
CAUTION: THIS ITEM OF THE SPECIAL
FUNCTIONS MENU IS TYPICALLY RESERvED FOR
CERTIFIED TECHNICIANS. ENTERING NUMBERS
OTHER THAN
THE SEvEN DESCRIBED BELOW COULD RESULT
IN PROGRAM AND CALIBRATION LOSS.
With this screen it is possible to activate the
following features:
• Fast Cool With Vacuum On (for cooling muffle
to entry temp between programs)
Lowers the lift and runs the vacuum pump until the
furnace reaches the entry temperature for a program.
To activate this function, start a program with an
entry temperature lower than the current temperature.
• Wide or Narrow Printer
Select full-sized 8
1
/
2
x 11 inch paper or receipt size
(Whip Mix Thermal Printer) paper.
• Enable Program Password Protection
(Call Whip Mix.)
• Use Timed Press Yes/No
Changes preference between Re-Press and
Timed Press, press programs are factory set.
• Print Form Yes / No
Tells the furnace to prompt you to print a form at the
end of a program. (The furnace will ask for time and
date at power up.) The time and date should be
reset daily.
• Load Code from “Blue Smart Box”
Enables you to order and upgrade software.
To access one of seven functions, do the
following:
1. Press the
Special Functions
button.
2. Turn the
Select Knob
counter-clockwise to select
CALIBRATE OVEN.
3. Press the
Next
button.
4. Turn the
Select Knob
to select the numerical
password needed.
Note:
In order to run any In-Ceram
®
program, In-Ceram
®
must be enabled (Pro Press 100 only). Call Whip Mix
service technician if In-Ceram
®
program does not run.
PASSWORD
FUNCTION:
NUMBER
1. Fast Cool with Vacuum On
314
2. Wide or Narrow Printer
320
3. Enable Program Password Protection — (Call Whip Mix)
Protects programs 70 and above
from alteration
4. Use Timed Press Yes/No —
310
If
No
is selected, then repress will
(Pro Press 100)
automatically include four minutes
press time on top of the time already
selected for the program
5. Print Form Yes/No
327
6. Load Code from “Blue Smart Box”
350
5. Press the
Next
button.
15946 Pro Series English.indd 17