30
Pro Series
Furnace Operations Manual
NEXT = RAISE TBL
Figure 39
NEXT = RAISE TBL
Figure 41
TIMED PRESS = NO
Figure 40
PRESSING
Figure 42
RE-PRESSING
Figure 43
Running a Pressing Program
(Pro Press 100 only)
1. If the muffle temperature is below the entry temperature
specified in the program, the table will raise to the
closed position while the temperature rises. If the muffle
temperature is above the entry temperature specified in
the program, the table will remain down while the muffle
cools. When the entry temperature is reached, the furnace
will begin to beep continuously. The display will read:
2. After Pressing the
Next
button, the table will lower.
Place the ring onto the firing table and press the
Next
button.
3. The Pressing program will begin running.
Running a Re-Press Program
To run a Re-Press Program, Calibration Password number
310 must be set to “Timed Press = No”
Press
Special Functions
Key, then rotate knob to the
“Calibration Password” prompt and press the
Next
key.
At the password entry prompt rotate the knob until the
display says “310” and press
Next
key.
4. The temperature will now rise to the final temperature
selected in the program. When the final temperature
is reached, the hold time will begin.
5. When the hold time has expired the display will
read as shown below. The furnace will begin the
first press. The first press will continue for four
minutes. After the first press has been completed
re-pressing will occur if password 310 is activated.
(See the Calibrate Oven section of this manual for
further information.)
When running a re-press program the furnace will
automatically press for four minutes and then the
additional “Re-Press” time you add in the program
parameters.
2. After pressing the
Next
button, the table will lower.
Place the ring onto the firing table and press the
Next
button.
3. The Pressing program will begin running.
6. The display will now say RE-PRESSING and the
furnace will begin to re-press the work for the amount
of time specified in the program. When the re-press
time has expired, the press will fully retract and the
table will lower.
Rotate the knob until the screen looks like the one above
and press
Next
key. This has activated the Re-Press mode.
1. If the muffle temperature is below the entry tempera-
ture specified in the program, the table will raise to
the closed position while the temperature rises. If the
muffle temperature is above the entry temperature
specified in the program, the table will remain down
while the muffle cools. When the entry temperature is
reached, the furnace will begin to beep continuously.
The display will read as shown below:
15946 Pro Series English.indd 30
5/9/08 2:51:12 PM