E V E N T S P A N E L
page 31
D-12 / July 2006
To change the control mode, begin by pressing and holding the
PREVIEW SCROLL knob until the display reads “Admin” and the TAKE
button lights (if the surface is currently in Admin mode the ARM button will
also light). Turn PREVIEW SCROLL until the desired new mode (Admin,
User, or Guest) is showing in the display and press TAKE. Turn PREVIEW
SCROLL again to select the first digit of the password. Default passwords,
which may be changed in XPoint, are “1234” for Admin, “2222” for User,
and “0000” for Guest. After dialing up the first character of the password,
press TAKE. Then dial up the second digit. Continue this procedure until
the four characters have been entered. Upon pressing TAKE after entering
the fourth character, the display will read “Okay...” if you were successful
and “Sorry...” if you were not. When finished, turn PREVIEW SCROLL
until the display reads “<<Exit” and press TAKE to finish the mode select
operation.
The ARM button lights as you select the mode that the surface is
currently in. If you press TAKE when displaying the current mode, the
display will switch to “Okay...” and you will not need to enter the password.
If you stop partway through the procedure, the mode selection process will
time out after about 15 seconds.
Once a given control mode is selected for a surface, that setting will
persist through a power cycle or surface reset.
Routing (XY Controller) Section
This section is a multi-use X-Y controller. Rotary knobs are provided
for selecting Sources and Destinations. TAKE buttons are provided for
both sources and destinations.
The information displayed in the eight
character SOURCE and DESTINATION
windows depends on which SET button is
pressed. Signal source and destination vis-
ibility is set in the XPoint GUI. Dobby the
DESTINATION knob to step through a list
of routes where the mixer signal is routed to
multiple destinations.
Control variations:
Input SET switch pressed:
SOURCE acts as source selector for input fader.
DESTINATION controls IFB (BUS MINUS) routing.
AUXx master SET switch pressed (MSTR SEND pressed):
SOURCE - not used
DESTINATION – used to route AUX bus to an output.
MXMx Master SET switch pressed (MSTR MXM pressed):
SOURCE – displays/routes Confidence feed source.
DESTINATION – used to route MXM x bus to an output.