M A S T E R P A N E L
page 3 – 22
E-1 / Apr 2010
For convenience, Wheatstone uses the following convention for IP Addressing in
the WheatNet-IP system:
1. The IP Address of a BLADE is equal to the BLADE ID plus 100; i.e.
BLADE 3 = 192.168.87.103
2. The IP Address of a control surface is equal to the Engine BLADE ID plus 200;
i.e. Engine BLADE = 5, Surface IP Address = 192.168.87.205
In most cases, you will want the Use Default Signal Map button to be ON, to insure
that the output signals are properly mapped. This insures that the surface outputs
appear at the designated connectors on the Console Blade. If you want to re-arrange
or re-purpose the outputs, switch this button to OFF.
When done, simply press APPLY to finalize these
settings and the surface will request a reboot.
Select YES from the dialog box and the surface
will reboot.
Once the surface has been rebooted navigate to the
Options Tab and select Network Settings from the
drop down menu. If all information was entered prop-
erly the BLADE
STATUS will display CONNECTED. The E-Series surface has
been successfully configured.