![Westgate DV48 Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/westgate/dv48/dv48_owners-manual_963983043.webp)
43
S
TART
-U
P
& O
PERATION
N
ORMAL
S
OUNDS
D
URING
O
PERATION
:
Table 7: Normal Sounds
Component
Sound & Reason
DV48 & Fascia
Creaking when heating up or cooling down.
Burner
Light pop or poof when turned off; this is more common with LP units.
Pilot Flame
Quiet whisper while the pilot flame in on.
Gas Control Valve
Dull click when turning on or off, this is the valve opening and closing.
R
EMOTE
C
ONTROL
O
PERATIONS
:
The Proflame GTMF is a modular remote control system that directs the functions of the DV48. The Proflame
GTMF is configured to control the on/off main burner operation, its flame levels and provides on/off and Smart
thermostatic control of the appliance. The system controls a remotely actuated 120V/60Hz power outlet, fan speed
through six (6) levels and has a constantly powered 120V/60Hz power outlet.
WARNING
THE TRANSMITTER AND RECEIVER ARE RADIO FREQUENCE DEVICES. PLACING THE RECEIVER IN OR
NEAR METAL MAY SEVERELY REDUCE THE SIGNAL RANGE.
ATTENTION!
- TURN “OFF” THE MAIN GAS SUPPLY OF THE APPLIANCE DURING INSTALLATION OR MAINTENANCE
OF THE RECEIVER.
- PLACE THE RECEIVER’S 3 POSITION SLIDER SWITCH IN THE “OFF” POSITION DURING
INSTALLATION OR MAINTENANCE.
- TURN “OFF” MAIN GAS SUPPLY TO THE APPLIANCE PRIOR TO REMOVING OR REINSERTING THE
BATTERIES IN THE RECEIVER.
- DURING APPLIANCE INSTALLATION/MAINTENANCE OR IN CASE OF REMOTE CONTROL
MALFUNCTION TURN OFF THE FAN CONTROL MODULE USING THE “ON/OFF” MAIN POWER SWITCH
ON THE FRONT PANEL OF THE FCM.
T
ECHNICAL
D
ATA
Transmitter (Remote Control):
Supply voltage 4.5 V (three 1.5 V AAA batteries)
Ambient temperature ratings 0 - 50 °C (32 - 122 °F)
Receiver:
Supply voltage 6.0 V (four 1.5 V AA batteries)
Fan Control Module:
Supply voltage/frequency: 120 V / 60 Hz
Aux switched output: 120 V / 60 Hz / 2 A
Fan speed output: 120 V / 60 Hz / 1 A
rt
S
YSTEM
D
ESCRIPTION
:
The Proflame Remote Control System consists of three (3) elements:
1. Proflame Transmitter.
2. Proflame Receiver and a wiring harness to connect the Receiver to the gas valve, stepper motor and Fan Control
Module.
3. Proflame Fan Control Module (FCM)
Содержание DV48