I
NSTALLATION
S
ET
-U
P
E
LECTRICAL
H
OOK
-U
P
:
LP G
AS
C
ONVERSION
:
Figure 52: Removing the hood.
30
orifice. Remove it by rotating it counter-clock wise until it is free of the pilot assembly (Figure 53).
7. Ensure that the pilot orifice you are about to install is the correct orifice. LP orifices have a groove cut around the
top of the orifice. See Figure 54 for help to identify these parts. The orifice size is stamped into the orifice. The
correct orifice sizes for the DV48 are
LPG - 35 and NG - 62.
8. Install the correct orifice and replace the pilot hood. The pilot hood has an indexing notch which must be align
with the pilot base. Ensure the pilot hood is properly located and that the spring holding the pilot hood is properly
engaged. Delayed ignition may be the result of an improperly installed pilot hood.
WARNING: This conversion kit shall be installed by a qualified service agency in accordance
with the manufacturer’s instructions and all applicable codes and requirements of the authority
having jurisdiction. If the information in these instructions is not followed exactly, a fire,
explosion or production of carbon monoxide may result causing property damage, personal
injury or loss of life. The qualified service agency is responsible for the proper installation
of this kit. The installation is not proper and complete until the operation of the converted
appliance is checked as specified in the manufacturer’s instructions supplied with the kit.
An electrical junction box is provided and fastened to the right side of
the fireplace. Power needs to be brought to the electrical junction box.
The power for the various control components are all provided from
the fan control module. Install the provided electric outlet and cover
and plug the the fan control module into it. See the Rating Label for
the listed electrical requirements.
When installed, the DV48, must be electrically grounded in accordance
with local codes or, in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA
C22.1.
WARNING
Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding) plug
for your protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do not
cut or remove the grounding prong from this plug.
Figure 51: Location of Electrical Hook-Up.
1. Ensure all the components of the conversion kit are accounted
for. There should be a pilot orifice, left & right for the glass tray
orifices, left & right for the log burner orifices, regulator diaphram,
servo regulator, and conversion label.
2. If the unit has already been connected to a gas supply, shut off
the gas supply to the unit.
2. If the unit has been run, shut off and allow cooling to room
temperature.
3. Remove the fireplace door. (see
D
OOR
R
EMOVAL
AND
I
NSTALLATION
).
4. Remove the burner, burner accents and firebox liners. (see each
applicable section in this manual)
5. The pilot hood is held in with spring pressure. Remove the hood
by pulling it directly up from the pilot assembly (Figure 52).
6. Insert a 3/32” or 4mm Allen wrench into the top of the pilot
Содержание DV48
Страница 52: ...WIRING HARNESS 52 ...