m
2000D
technical manual
Page 5
Figure 2: Remote DLC slave Corner & Section grouping
The following restrictions apply to allocating cells for hopper or sectional scales:
q
Hopper Scales
Hopper scale corners can be grouped on a single DLC, they cannot be spread across
two DLC terminal boxes. Hopper scales can be grouped from any of the cells on a
particular DLC slave terminal box.
q
Sectional Scales
A scale that uses sections will function in such a way that sections must be paired
together, across from each other as outlined in
Figure 2
. Two DLCs may be used for a
sectional scale allocation. Sections are allowed to span across DLC slaves. For
instance, the user might apply all 16 cells as a sectional scale which will provide 4
sections on the
P
rimary DLC and 4 sections on the
S
econdary DLC, etc.
INTRODUCTION
+SIG
- SIG
SHLD
+EXC
- EXC
+SIG
- SIG
SHLD
+EXC
- EXC
+SIG
- SIG
SHLD
+EXC
- EXC
+SIG
- SIG
SHLD
+EXC
- EXC
- EXC
+EXC
SHLD
- SIG
+SIG
- EXC
+EXC
SHLD
- SIG
+SIG
- EXC
+EXC
SHLD
- SIG
+SIG
- EXC
+EXC
SHLD
- SIG
+SIG
STATUS
LINK
TX
DIGITAL LINK
ID
SELECT
PRM
SEC
Содержание m2000D
Страница 17: ...m2000D technical manual Page 12 Intentionally Left Blank...
Страница 23: ...m2000D technical manual Page 18 Intentionally Left Blank...
Страница 29: ...m2000D technical manual Page 24 Intentionally Left Blank...
Страница 43: ...m2000D technical manual Page 38 Intentionally Left Blank...