530 Reset Corner Field adjustment entries: calibration command
Field adjustment entries are the corner span corrections applied to corners during
calibration, these entries would be cleared for new scale installations. Normally command
530 is performed directly
after
a scale was allocated using commands 520 or 521.
This command only affects the selected scale under calibration.
This command will reset the field span and zero adjustment entries for the scale in
question.
In scales containing multiple load cells it is often required to do small corrections to
selected load cells in order to make the scale’s response consistent for any weight
placement. Commands 532/531 are used to make these small corrections to the corner/cell
selected by the user using the [TARE] key. If the user is not satisfied with the current span
adjustment values, command 530 can be used to clear the correction values and the user
can then repeat the adjustment process using commands 532/531 if required.