User Guide
6. Management
6.7 Firmware Upgrade
Supported Load Balance Policies: FOO RR RRWS LQD WP LB
Path ID State SCSI Address Weight
---------------------------------------------------------------------
0000000077000051 Active/Optimized 000|000|081|000 0
Adapter: Avago Adapter, SAS3 3008 Fury -StorPo... (B|D|F:
005|000|000)
Controller: 46616B65436F6E74726F6C6C6572 (State: Active)
0000000077000038 Active/Optimized 000|000|056|000 0
Adapter: Avago Adapter, SAS3 3008 Fury -StorPo... (B|D|F:
005|000|000)
Controller: 46616B65436F6E74726F6C6C6572 (State: Active)
MPIO Disk22: 02 Paths, Round Robin, ALUA Not Supported
SN: 5001173100DED6A8
Supported Load Balance Policies: FOO RR RRWS LQD WP LB
Path ID State SCSI Address Weight
---------------------------------------------------------------------
0000000077000050 Active/Optimized 000|000|080|000 0
Adapter: Avago Adapter, SAS3 3008 Fury -StorPo... (B|D|F:
005|000|000)
Controller: 46616B65436F6E74726F6C6C6572 (State: Active)
0000000077000037 Active/Optimized 000|000|055|000 0
Adapter: Avago Adapter, SAS3 3008 Fury -StorPo... (B|D|F:
005|000|000)
Controller: 46616B65436F6E74726F6C6C6572 (State: Active)
l.
Verify that the MPIO results appear.
Note:
An ESM fault LED will illuminate after upgrading the first ESM. This is
expected behavior and is due to the FW mismatch between ESMs. Once both
ESMs have been upgraded the fault LEDs will turn off.
Step 3 :
Verify the firmware upgrade using sg_scan.
a.
Issue the following command:
sg_scan -s | findstr /i encl
b.
Identify the firmware upgrade version from the output. The latest version number should
match the version labeled in the firmware filename. The version number follows the
vendor and product ID,
HGST 2U24_STOR_ENCL
, for each associated SCSI device in the
output. The firmware has been upgraded to version 0441 shown in the example below.
SCSI0:1,62,0 claimed=0 pdt=dh HGST 2U24_STOR_ENCL
0441
SCSI0:1,124,0 claimed=0 pdt=dh HGST 2U24_STOR_ENCL
0441
78