12
UM380 03 010
InterChange iQ 2000 and iQ 2000plus
You are returned to the higher menu level.
The default values and correct time and date are now set and you are ready to proceed with
protocol configuration.
2.5.3 Protocol Configuration
The menu displays:
Select Configuration Option?
To change the management connection from direct/remote via modem to ethernet, the user
needs to configure the InterChange iQ 2000 or iQ 2000plus
Console
. Type:
CONS <Enter>
The Configuration Wizard asks for the console parameter:
Configure which console parameter ?
To list the menu of available parameters, type:
? <Enter>
To display the present configuration, type:
DISP <Enter>
The present configuration is shown:
console is over serial
BAUD rate: 38400
Flow Control: XON/XOFF
To change the configuration, type:
CONF <Enter>
The Configuration Wizard asks:
Console type ?
Type:
ETH <Enter>
for Ethernet or
SER
for Serial
For Ethernet, the Configuration Wizard then asks:
IP address ?
This is an address for the unit, which the user must obtain and make a note of, from the
network administrator. The format of the address (and the default) is 0.0.0.0.