C Cabling Specifications
This Appendix specifies those cables which are to be supplied by the user if necessary for
the configuration.
Connection to ISDN Networks and Equipment
These are connections to the Network / User. Each unit has two ISDN ports labelled Port 1
and Port 2.
Conversion Type
Conversion
PORT 1
PORT 2
Q.931 / DPNSS
Q.931
DPNSS
Connection to ISDN equipment and network is by either 75 Ohm unbalanced or 120 Ohm
balanced cables, terminated at the Interchange iQ end in a pair of BNC connectors for 75
Ohm or an RJ45 connector for 120 Ohm.
Management Terminal Connection
When on-line control of InterChange iQ 2000 is required a permanent connection must be
established to the 9-way female D-type connector labelled
Management
, at the rear of the unit.
The maximum cable length is 30 metres (100 ft).
A terminal runs at 38400 baud, 8 data bits, 1 stop bit, no parity, with XON/XOFF flow control.
If a modem link is being used for the management terminal connection, connect the modem
to the management port using a straight through DTE-DCE cable, with a minimum of TX,
RX and Signal Ground pins connected. The modems must have XON/XOFF pass through
enabled.
Figure 47: Management Terminal Connection.
Modems do not have to be from the same manufacturer but
must
be capable of working with
compatible protocols and capable of certain functions.