30
198201 R17
Figure 12.
Side draw opening using the retrofit sheet as a template
Page 18
Remove center horizontal
bolts, top and bottom
195477
Re-attach
drill 13/32" mounting
using retrofit sheet
template
hrough
sheet
Use retrofit sheet as
a template to cut
discharge opening
and mounting holes
Caulk around
retrofit sheet
IMPORTANT:
For some specially designed bins, a heavier wall sheet may be provided for the discharge
opening. This will be noted in the special manual accompanying the bin. For these cases only, a side draw
reinforcing sheet will not be provided.
SIDE DRAW REINFORCING SHEET
For some Bin models a shorter reinforcing sheet needs to be added behind the opening to reinforce this
area. The views below describes the installation procedure and the chart explains which Bins require the
reinforcing sheet.
- Remove some existing horizontal seam bolts from the wall sheet that receives the sidedraw outlet.
- align and bolt the reinforcing sheet on to the wall sheet.
- Field drill the remaining assembly holes (13/32") using the reinforcing sheet as a template. Install 3/8 X
1.5" bolts and nuts
- Cutout discharge opening using the retro fit sheet as a template.
- Attach discharge assembly to outside and last baffle to inside.
SIDE DRAW REINFORCING SHEET WHERE USED CHART
CEW's
ALL
SHORT SHEET REQUIRED FOR ALL BINS NOT ALREADY HAVING
FULL HEAVIER SHEET
CEN's
WITH DISCHARGE IN
2nd TIER
FROM
BOTTOM
SHORT SHEET REQUIRED FOR BINS UP TO
6023, 7220,7518, 7817
WITH DISCHARGE IN
5th TIER
FROM
BOTTOM
SHORT SHEET REQUIRED FOR BINS UP TO
7223, 7521, 7820
NOTE: The Side Draw reinforcing sheet can be used for all applications where the flanged outlet is
penetrating an 8 gauge wall sheet or less..
7. Caulk around the retrofit sheet
8. Insert 3/8 x 1.5" bolts through the wall sheet and the retrofit sheet
9. Field drill the remaining assembly holes (13/32") using the reinforcing sheet as a template.
10. Install 3/8 X 1.5" bolts and nuts.
11. Cut out the discharge opening using the retro fit sheet as a template.
12. Attach the discharge assembly to the outside and the last baffle to the inside.
Note
The side draw reinforcing sheet can be used for all applications where the flanged outlet is
penetrating an 8–gauge wall sheet or less.
5.6. Side Draw Reinforcing Sheet Installation (60’ — 108’ Bins)
For some bin models a shorter reinforcing sheet needs to be added behind the opening to reinforce this area.
The following illustrations show the installation procedure.
1. Remove the center horizontal bolts, top and bottom.
2. Remove some existing horizontal seam bolts from the wall sheet that receives the side draw outlet.
3. Align and bolt the reinforcing sheet on to the wall sheet.
5. ASSEMBLY
SIDE DRAW DISCHARGE – WIDE-CORR® CENTURION® GRAIN BIN