5.2.6 Baffle Installation Notes
When installing baffles, the flanges on the baffles will sometimes lay across the horizontal wall sheet seams and
come up against the protruding bolt shanks. By tightening the baffles there will be localized interference which
pushes the wall sheet outwards at this location. When this occurs, reverse the bolt to avoid interference.
1. For stiffened bins, 48' diameter and smaller, install 2 baffle angles (195476) per baffle as illustrated.
2. Some bins with side discharge systems must have extra wind rings installed. Consult bin installation manual
for location and quantity of wind rings.
3. Center all sidedraw components horizontally between uprights.
Figure 9.
Sample Layout
Page 16
- OUTLET OPENING MUST BE CENTERED
IN MIDDLE OF WALL SHEET
- BAFFLES MUST BE ORIENTED WITH NARROW
END OF OPENING FACING UP AS SHOWN
QUANTITIES AND STARTING
LOCATION WILL VARY
PROBABLE HARDWARE
INTERFERENCE
AT HORIZONTAL SHEET OVERLAP,
REVERSE HARDWARE ORIENTATION
WITH BOLT TO INSIDE
= NO INTERFERENCE WITH BAFFLE
NORMAL HARDWARE ORIENTATION,
BOLT ON OUTSIDE
= MAJOR INTERFERENCE WITH BAFFLE
BAFFLE
INSIDE OF BIN
OUTSIDE OF BIN
HORIZONTAL WALLSHEET SEAM
MOVE RUBBER
WASHER TO
OUTSIDE
IMPORTANT: ORIENT BAFFLES WITH
NARROW END OF OPENING AT THE TOP.
CATASTROPHIC BIN FAILURE COULD
RESULT IF BAFFLES ARE INSTALLED
INCORRECTLY
Adhere to the following baffle layouts to ensure
that the discharge opening is centered to wall
sheet.
66
70
23 TIERS
50
78
24 TIERS
BAFFLE LOCATION - 23 & 24 TIERS
When installing baffles, the flanges on the baffles will
sometimes lay across the horizontal wall sheet seams and
come up against the protruding bolt shanks. By tightening
the baffles there will be localized interference which
pushes the wall sheet outwards at this location. When this
occurs, reverse the bolt to avoid interference.
INSTALLATION NOTES
1. For stiffened bins, 48' diameter and smaller, install
2 baffle angles (195476) per baffle as illustrated.
2. Some bins with side discharge systems must have
extra wind rings installed. Consult bin installation
manual for location and quantity of wind rings.
3. Center all sidedraw components horizontally
between uprights.
• Outlet opening must be centered in the middle of the wall sheet
• Baffles must be oriented with the narrow end of the opening facing up as shown
Important
Orient the baffles with the narrow end of the opening at the top. Catastrophic bin failure could result if
the baffles are installed incorrectly.
SIDE DRAW DISCHARGE – WIDE-CORR® CENTURION® GRAIN BIN
5. ASSEMBLY