-- 18 --
Ⅰ
- 3.3
Ⅰ
- 3.4
5 . Press START button and run the machine.
6 . Drain off about 1 liter of the solution from clean water drain outlet and water discharge outlet each. Leave the
remaining solution in the system for over 2.5 hours.
;
7 . When time is up, drain off the remaining solution from clean water drain outlet and water discharge outlet, and
reconnect the wiring of top water level sensor.
8 . Fill 20 liters of pure water into top tank and drain off from clean water drain outlet and water discharge outlet
9 . Repeat the step 8 till there is no strange taste in water output from clean water outlet (Normally twice the
operation is enough). Replace back tank cover and top cover PIN.
Annex II
:
When low voltage protection of compressor on machine displays on screen, (LOWER PRESSER OF COMPRESSOR
PLS REPAIR AND RESTART) Reasons need to be identified and eliminated before restarting. When high Pressure
Protection of Compressor When showing on Machine Display Screen (HIGH PRESURE OF COMPRESSOR; PLS
REPAIR AND RESET HIGH PRESSER SWITCH TO RESTART) Then the machine is in a high-voltage protection;
Reasons need to be identified and eliminated before the machine can be restarted after manual reset, The installation
method is as follows
:
1. Turn off the power and open the front door of the machine. (Picture Ⅱ- 1.3)
2. Push the green button upward with your finger and hear a beep. (Picture Ⅱ- 1.4)
Ⅱ- 1.3
Ⅱ- 1.4