background image

“EASY” Confi guration

Activation of the GSM transmitter:
-   At least one element of the signal tower must be 

energized. Observe: As soon as the voltage is applied to 
the module, it is ready for reception for 10 minutes. After 
expiry of this time, it switches off.

-  For confi guration, the status LED on the topside must 

change from an approximate 5-second continuous 
illumination to a blinking signal (200 millisecond interval) 
with a 1-second break.

-   Dial the GSM transmitter’s number via your master tel-

ephone. Wait until the 2 beep acknowledgement signal 
is heard then hang up.

-   You will receive an confi guration SMS as confi rmation.
-   The GSM transmitter is ready for operation. An SMS is sent 

to the master telephone as long as a signal is applied to 
the tower for at least 30 sec (with operating lamp) or 60 
sec (without).

For an individual adjustment, please refer to the “EXPERT” 
Confi guration chapter.

“EXPERT” Confi guration

With the “EXPERT” confi guration, the GSM transmitter can be individually confi gured via SMS.

Procedure
-   Send an SMS (for structure and contents, please refer to the examples) to the GSM transmitter’s calling number.
-   The SMS can only be sent via the mater telephone.
-   Observe that the transmitter is energized.

Content of the Confi guration SMS

-   Each confi guration SMS must begin with “

conf,gsm1

“.

-   Do not use any semicolons.
-   Blanks, full stops and commas are permissible.
-   There is no case sensitivity with the SMS text.
-   The parameters are separated by blanks (

).

-   The alarm texts must be concluded with a semicolon. Alarm texts have a maximum text length of 120 ASCII characters, refer  

below. Text length limitations of your mobile phone may require one parameter to be changed at a time.

-   You may request a confi rmation from the GSM transmitter by adding a “

+

” with a blank as the last character of the SMS.

-   Only the master telephone can receive a confi rmation SMS.

confi gurable parameters

Basic setting

Description

c1:

 

Device ID (Name)

last 6 digits of the 
IMEI-No.

Max. 12-digit individual ASCII text (optional), can be assigned during the 
GSM transmitter’s confi guration.

c2:

 

Master telephone calling No.

-

Max. 20-digit calling number in international format (with “

+

”)

c3:

 

Operator 2 calling number

-

Max. 20-digit calling number in international format (with “

+

”) 

(optional)

c4:

 

Operator 3 calling number

-

Max. 20-digit calling number in international format (with “

+

”) 

(optional)

c5:

 

Master input mask

1111 

4-digit information, as to which inputs generate which messages in 
which form:

0

 - Input is ignored 

1

 - Input generates SMS 

2

 - Input generates voice call

3

 - Input generates voice call and SMS

c6:

 

Operator 2 input mask
(optional)

0000

c7:

 

Operator 3 input mask
(optional)

0000

c8:

 

Duration of the alarm call

10

In seconds, value range 2 to 60

c9:

 

Operating mode

0

Information on various operating states 

0

 - basic setting 

1

 - “External control” mode

c10:

 

Mask for external control

0001

One of the 4 levels is used as “Alarm deactivated” input. 
The selected level is defi ned in the mask.

c11:

 

Alarm text 1

Signal 1

ASCII text, max. 120 characters 
(conclude with “

;

”!)

c12:

 

Alarm text 2

Signal 2

ASCII text, max. 120 characters 
(conclude with “

;

”!)

c13:

 

Alarmtext 3

Signal 3

ASCII text, max. 120 characters 
(conclude with “

;

”!)

c14:

 

Alarmtext 4

Signal 4

ASCII text, max. 120 characters 
(conclude with “

;

”!)

1111: 1st digit = 1st level, 2nd digit = 2nd level, 3rd digit = 3rd level, 4th digit = 4th level.
Voices calls are non-chargeable calls.
Examples:
1.   Changing the device ID to “Machine1” with confi rmation SMS:

conf,gsm1

c1:

Maschine1

+ „+“ 

confi 

rmation

2.   Additional message to a second telephone connection (e.g. land line connection), voice call and SMS, with signal applied 

to the signal tower’s bottom element with confi rmation SMS:

conf,gsm1

c3:

+4974249557222

c6:

3000

+

Default Setting

Default setting mode:
A GSM transmitter without the number of a master telephone 
is in the default setting mode. The GSM transmitter can be 
confi gured.
Resetting to default setting mode:
Send an SMS to the GSM transmitter with the IMEI No. (15 
characters) and, following a blank, enter “reset”!
Example: 351266000233017

reset

You will receive no confi rmation SMS. An automatic switch-
off of the GSM transmitter after 10 minutes signals the reset to 
the default setting mode.

Status Query

You may query the GSM transmitter’s status via the master 
telephone. Send an SMS: “ST+”. 
You will receive a text message showing the status of the 
GSM transmitter as per the table below.
Example: Send SMS: ST+

Index Designation

Description

1

Device ID

2

Status of the 4 inputs

4-digit number

3*

System run time in seconds

1 to 8-digit 
number

4*

Number of all sent SMS

1 to 8-digit 
number

5*

IMEI

15-digit number

6

Alarm activated / deactivated „ON“ / „OFF“

Information marked with “*” can be obtained by an SMS with 
STX+”. The seconds are counted from the GSM transmitter’s 
activation. “4*” counts from activation or from the counter’s 
last calibration.

Resetting the SMS Counter

The “STX RSMS” SMS deletes the current counter reading 
(control for pre-paid cards). With “+”, you can request a 
confi rmation SMS.
Example: STX RSMS

Query of the current confi guration

Send a confi guration SMS to the GSM transmitter. The SMS 
has no confi gurable contents. With a blank and a suffi xed 
+”, request a confi rmation SMS.
Example: conf,gsm1

+

Troubleshooting

If faults are detected during the start-up phase they are 
signalled by blinking sequences via the status LED 
(see illustration under ‚EASY‘ confi guration):
-   2 x blinking (200msec interval), 1-second break:

   no SIM card recognized

-   3 x blinking (200 msec interval), 1-second break:

   PIN number not set to 0000

-   4 x blinking (200 msec interval), 1-second break:

   Hardware fault. Switch the GSM transmitter off and 

rectify the fault. 

Regular operation is not possible in these states.

The GSM transmitter is OK, however, no messages are 
received by your mobile phone:
-  Deactivate the calling number suppression function of 

the master telephone!

S I G N A L T E C H N I K

Hotline: +49 (0) 74 24  95 57-222, 

www.werma.de (FAQ)

310_840_011_0605_gb.indd   2

310_840_011_0605_gb.indd   2

06.06.2005   11:22:36

06.06.2005   11:22:36

Содержание 646 700 55

Страница 1: ...ur Verfügung wenn eine konstante Spannungsversorgung gewährleistet ist Verwenden Sie in Verbindung mit dem GSM Funkelement möglichst eine Betriebsmeldeleuchte Hinweis Bitte tragen Sie die wichtigen Nummern zum Nachschlagen hier ein Ein Ausschalten des GSM Funkelements Die Alarmfunktionen lassen sich deaktivieren ohne die Konfigurationen zu verändern 1 durch Anrufen des GSM Funkelements gebührenfrei...

Страница 2: ...n mit abschließen c12 Alarmtext 2 Signal 2 Ascii Text max 120 Zeichen mit abschließen c13 Alarmtext 3 Signal 3 Ascii Text max 120 Zeichen mit abschließen c14 Alarmtext 4 Signal 4 Ascii Text max 120 Zeichen mit abschließen 1111 1 Ziffer 1 Stufe 2 Ziffer 2 Stufe 3 Ziffer 3 Stufe 4 Ziffer 4 Stufe Voice Call ist ein gebührenfreier Anruf Beispiele 1 Ändern der Geräte ID auf Maschine1 mit Bestätigungs S...

Страница 3: ...f the GSM transmitter are only avail able with constant supply voltage application If possible use an operating signal ling lamp in connection with the GSM transmitter Information Please enter the numbers for refer ence purposes Switching the GSM Transmitter On and Off The alarm functions can be deactivated without changing the configuration 1 By calling the GSM transmitter non chargeable 2 By send...

Страница 4: ...ctivated input The selected level is defined in the mask c11 Alarm text 1 Signal 1 ASCII text max 120 characters conclude with c12 Alarm text 2 Signal 2 ASCII text max 120 characters conclude with c13 Alarmtext 3 Signal 3 ASCII text max 120 characters conclude with c14 Alarmtext 4 Signal 4 ASCII text max 120 characters conclude with 1111 1st digit 1st level 2nd digit 2nd level 3rd digit 3rd level 4...

Страница 5: ...l quelconque Attention Certaines fonctions par ex inter rogation de l état de l élément radio GSM ne sont disponibles que lorsqu une alimentation en tension constante est garantie Utiliser si possible un voyant lumineux de fonctionnement avec l élément radio GSM Information Inscrire les numéros pour les avoir à portée de la main Enclenchement et coupure de l élément radio GSM Les fonctions alarme ...

Страница 6: ... le masque c11 texte alarme 1 signal 1 texte Ascii 120 caractères maxi confirmer avec c12 texte alarme 2 signal 2 texte Ascii 120 caractères maxi confirmer avec c13 texte alarme 3 signal 3 texte Ascii 120 caractères maxi confirmer avec c14 texte alarme 4 signal 4 texte Ascii 120 caractères maxi confirmer avec 1111 1e chiffre 1e niveau 2e chiffre 2e niveau 3e chiffre 3e niveau 4e chiffre 4e niveau L ap...

Отзывы: