Troubleshooting and Maintenance
6-1
6
TROUBLESHOOTING AND MAINTENANCE
This chapter:
- Lists all faults and alarms that may occur.
- Indicates the possible causes of each fault and alarm.
- Lists most frequent problems and corrective actions.
- Presents instructions for periodic inspections and preventive
maintenance in the equipment.
6.1 OPERATION OF THE FAULTS AND ALARMS
When a fault is detected (“FAULT” (FXXX)):
The PWM pulses are blocked;
The keypad displays the "FAULT" code and description;
The “STATUS” LED starts flashing red;
The output relay set to "NO FAULT" opens;
Some control circuitry data is saved in the EEPROM memory:
- Keypad and EP (Electronic Pot) speed references, in case the function “Reference backup” is enabled in
P0120;
- The "FAULT" code that occurred (shifts the last nine previous faults and alarms);
- The state of the motor overload function integrator;
- The state of the operating hours counter (P0043) and the powered-up hours counter (P0042).
Reset the inverter to return the drive to a “READY” condition in the event of a “FAULT”. The following reset
options are available:
Removing the power supply and reapplying it (power-on reset);
Pressing the operator key
(manual reset);
Through the "Reset" soft key;
Automatically by setting P0206 (auto-reset);
Through a digital input: DIx=20 (P0263 to P0270).
When an alarm situation ("ALARM" (AXXX)) is detected:
The keypad displays the "ALARM" code and description;
The “STATUS” LED changes to yellow;
The PWM pulses are not blocked (the inverter is still operating).
Содержание 105 A
Страница 3: ...2 Revision Description Chapter 1 First Edition 2 General Revision Summary of Revisions...
Страница 17: ...General Instructions 2 10 2...
Страница 49: ...Installation and Connection 3 32 3...
Страница 63: ...First Time Power Up and Start Up 5 10 5...
Страница 79: ...Option Kits and Accessories 7 6 7...
Страница 88: ...Technical Specifications 8 9 8 Frame B Figure 8 3 Inverter dimensions frame B Dimensions in mm in...
Страница 89: ...Technical Specifications 8 10 8 Frame C Figure 8 4 Inverter dimensions frame C Dimensions in mm in...
Страница 90: ...Technical Specifications 8 11 8 Frame D Figure 8 5 Inverter dimensions frame D Dimensions in mm in...