Initial Operation
6.1 Overview of functions
Denomination
Function
Page
run
Leave the configuration menu
SP 1/SP 2, SP U
Teach-In the Sensor
PL
Change Teach-In Mode
SL
Change Switching Logic
OUP
Set Output Function
AnA
Set analog Voltage Output or Current Output
EP
Expert menu
CL
Select Characteristic Curve
FL
Filter Settings
Fun
Select Operating Mode
Ad
Participant Adress Multiplex
nr
Fix Number of Multiplex Participants
Sen
Select Ultrasonic Cudgel
rES
Reset
6.2 Delivery status
Technical Data
UMF402U035
UMF303U035
Teach-In Input
Enabled
Switching Logic (SL)
Normally open (NO)
Teach Mode (PL)
Foreground Teach-In
Output Function (OUP)
Switching Output
Operating Mode (Fun)
Normal
Lock Control Panel
Enabled
Sonic Conde (SEn)
Standard
Temperature Mode
Internal
Filter (FL)
0
Analog Mode (AnA)
0...10 V
Characteristic Curve (CL)
0 = Curve rising
Switching Point (SP U) in Teach-In mode
Foreground Teach-In
400 mm
3000 mm
Switching Hysteresis
2 mm
30 mm