Technical Data
4. Technical Data
UMF402U035
UMF303U035
Ultrasonic
Working Range
50...400 mm
200...3000 mm
Measuring Range
350 mm
2800 mm
Reproducibility, maximum
1 mm
4 mm
Linearity Deviation
3 mm
4 mm
Resolution
0,1 mm
0,3 mm
Ultrasonic Frequency
300 kHz
120 kHz
Opening Angle
<12°
< 14°
Service Life (Tu = 25 °C)
100000 h
100000 h
Switching Hysteresis
2 mm
30 mm
Electrical Data
Supply Voltage
18…30 V DC
18…30 V DC
Current Consumption (Ub = 24 V)
<40 mA
<40 mA
Switching Frequency
20 Hz
3 Hz
Response Time
25 ms
167 ms
Temperature Range
–25...60 °C
–25…60 °C
Switching Outputs
1
1
Switching Output Voltage Drop
<2,5 V
<2,5 V
PNP Switching Output/Switching Current
100 mA
100 mA
Analog Output
0…10 V
0…10 V
Analog Output
4…20 mA
4…20 mA
Synchronisation
yes
yes
Multiplex Mode
yes
yes
Short Circuit Protection
yes
yes
Reverse Polarity Protection
yes
yes
Overload Protection
yes
yes
Interface
IO-Link
IO-Link
Mechanical Data
Adjustment
Teach-In
Teach-In
Housing
Stainless Steel
Stainless Steel
Degree of Protection
IP 67
IP 67
Connection
M12 × 1
M12 × 1
Protection Class
III
III
PNP NO/NC switchable
yes
yes
Error Output
yes
yes
Analog Output
yes
yes
IO-Link
yes
yes
The warm-up phase takes approx. 30 minutes. At the beginning of this time, the linearity deviation and the
reproducibility may deviate. During the warm-up phase, the values improve in the form of an exponential
function until the technical data are achieved. The sensor works with an internal temperature compensation
in order to compensate air temperature fluctuations. Via the IO link interface, you can also specify externally
determined temperature values.
Содержание UMF303U035
Страница 23: ...23 Reflex Sensor with Analog Output ...