11
Reflex Sensor with Analog Output
5.1 Causes for Triggering Error Indication (LED Plus Button)
• Too little ultrasonic is reflected.
• Very small objects, or objects which do not reflect sound well (sound-absorbing objects), are located
within the working range.
• Incorrect installation
• Object outside of the working range
• Strong sources of ultrasound within the axis of the sound waves
• Strong air turbulence
6. Initial Operation
An IO-Link master with port Class A must be used, as for port Class A pin 5 is not connected.
Connect the sensor to 18…30 V DC.
In order to enter the configuration menu press the Mode key for 5 seconds. By pressing the Mode key again
you change between the submenus.
The display shows the submenu and which setting is activated.
Example:
SL: Submenu: Change Switching Logic
no: Setting: NO
By pressing the Plus key the setting in the respective submenu is changed.
In order to leave the configuration menu, you have to change to the “Display mode (run)” submenu. By
pressing the plus key, you leave the configuration menu. You can directly jump to the display mode from
every submenu by pressing the Mode key for approx. 5 seconds.
Important: In order to prevent a demage of the keys please don't use sharp objects for setting.
Содержание UMF303U035
Страница 23: ...23 Reflex Sensor with Analog Output ...