EN
14
Settings
7. Settings
7.1 run (display mode)
By pressing the plus key, you leave the configuration menu.
7.2 SP U (Teach-In Switching Point)
Align Sensor to the object (SP U).
Press Plus key.
The dispay doesn't change from Distance Value and SP U.
Point is teached.
7.3 SP 1* (Teach-In first Point of the Window)
Align Sensor to the object.
Position the object to the first point (SP 1) of the Window you want to teach-in.
Press Plus key.
The dispay doesn't change from Distance Value and SP 1.
Point is teached.
7.4 SP 2* (Teach-In second Point of the Window)
Align Sensor to the object.
Position the object to the second point (SP 2) of the Window you want to teach-in.
Press Plus key.
The dispay doesn't change from Distance Value and SP 2.
Point is teached.
* NOTE!
Only possible if the Teach-In Mode ist set to Window“. View Chapter 7.5