19
Reflex Sensor with Analog Output
4
Multiplex Slave
The Sensor is in multiplex slave mode. Via pin 5, the master transmits tempo-
rarily delayed signals to the slaves so that they transmit consecutively clocked
ultrasonic impulses.
5
Multiplex Master
The Sensor is in multiplex master mode. It sends out impulses automatically to
the connected Slaves via Pin 5 (T/SY), in order that they all send out Ultrasonic
impulses one after another.
6
Mute
The Ultrasonic Emitter of the Sensor is switched off. Signals from other sensors
are not accepted either.
7.13 Ad*¹ (Set Multiplex Participants Address)
For each Multiplex Slave Sensor a participants address between 0 and 15 has to be
selected. In this order the Multiplex Slaves are then supplied with impulses by the
Multiplex Master.
*¹ NOTE!
Only possible if the Operating Mode is set to „Multiplex Slave“. View Chapter 7.12
7.14 nr*² (Set Number of Multiplex Participants)
The number of the Slave Sensors that are connected to a Master has to be entered
(max. 16), in order that the Master sends out the right number of impulses.
*² NOTE!
Only possible if the Operating Mode is set to „Multiplex Master“. View Chapter 7.12