50
EN
8. Condensed Start-Up Instructions
Start
Set all DIP
switches to off
Align the light curtain
mechanically
Press and hold the
enter button on the
receiver for 1 s
Do the
blanking alignment
and failure LEDs
blink?
Alignment degree
appears at the display
99 – very good
44 – not good
43 – beams masked
see table “Degree of alignment
against the distance between
transmitter and receiver”
Press and hold the enter
button on the receiver for 1 s
The receiver boots and
activates the outputs
The safety light
barrier is ready for
operation
yes
Improve
alignment
no
Is restart
inhibit
required?
Is contactor
monitoring
required?
Set the restart
inhibit DIP switch
Set the contactor
monitoring DIP switch
yes
yes
…
Distance transmitter – receiver
Without deflection mirror With 1 deflection mirror
With 2 deflection mirrors Degree of alignment
≤
3 m
≤
2,7 m
≤
2,4 m
96 imperatively necessary
3…7 m
(finger protection)
3…20 m
(hand protection)
2,7…6,3 m
(finger protection)
2,7…18 m
(hand protection)
2,4…5,6 m
(finger protection)
2,4…16 m
(hand protection)
96, 78, 68, 56 preferred
> 43 necessary
Tab.: Degree of alignment against the distance between transmitter and receiver
9. Inspection Instructions
The inspections described below serve to confirm compliance with specified safety requirements set forth in na-
tional/international regulations, in particular the safety requirements included in the machinery directive and the
directive concerning safety and health requirements for the use of work equipment (EC conformity).
The inspections also serve to detect influences which effect the device’s protective action, as well as any other un-
usual ambient influences.