45
Relay Unit Terminal Assignments
Required system components:
1 × emitter, 1 × receiver
1 × cable
1 × connector cable
1 × relay unit
From
Function
To
Relay Unit Connections
Terminal 1
NO, 13
Machine contact
Terminal 2
NO, 23
Machine contact
Terminal 3
NO, 24
Machine contact
Terminal 4
NO, 14
Machine contact
Terminal 5
NO, 43
Machine contact
Terminal 6
NO, 33
Machine contact
Terminal 7
NO, 34
Machine contact
Terminal 8
NO, 44
Machine contact
Terminal 9
OSSD 1
Pin 3 socket 1 (receiver)
Terminal 10
OSSD 2
Pin 6 socket 1 (receiver)
Terminal 11
Unused
Terminal 12
0 V Ground
Pin7 socket 1 (receiver)
Terminal 13
Unused
Terminal 14
Contactor monitor
Pin 5 socket 1 (receiver)
Terminal 15
24 V
Pin 2 socket 1 (receiver)
Terminal 16
Unused
DIP Switch Settings: Receiver
Serial Communication
Cascading
Timing
Restart Inhibit
8
7
6
5
4
3
2
1
ON OFF
Contactor Monitoring
Reduced Resolution
Fix Blanking
S1
6.2 Muting Module
The PMUT-X1P add-on module allows for muting mode operation with the light curtain. Certain objects can
be passed through the safety field without switching the safety output in muting mode. For example, mate-
rial can be fed through the safety field, although reach-in or step-in is nevertheless detected. The muting
module allows different types of muting and cyclic operation modes. The use is described in the operating
instruction of the muting module.