Well Straler RC-16B Скачать руководство пользователя страница 5

5

2. Commands of your appliance

Some advantages of the Well Straler new product generation:

Automatic ignition without steady pilot;

Precise digital temperature control in a range of ± 6 m from the heater;

Wireless RF remote control of all the functions of your heater in a range of ± 6m;

Four  different  operation  modes:  (ON/OFF – THERMOSTAT – WEEKLY

PROGRAM – COUNTDOWN TIMER);

Full automatic pre-programmed weekly program with 4 independent temperature

ranges each day, seven days a week.

IMPORTANT For  the  device  to  work  correctly,  the  emitter  and  receiver  must  be well  tuned to  each  other  (cfr.

LEARN, p.13). If the range is lower than 6 m, the antenna of the receiver (black wire on the side) must be moved. If

the receiver is in safety mode (one beep every 20 seconds), it has to be reset. In that case switch the receiver OFF,

and then again on REMOTE.

2.1. Transmitter

The transmitter operates on 2 AAA-size 1,5V batteries. We recommend the use of ALKALINE BATTERIES for maximum

operation performance. Insert batteries into the battery compartment on the back of the transmitter, positioning the (+) and

(-) ends of the batteries as indicated. Once batteries are inserted, the temperature will display. If this is not the case please

check that batteries are inserted properly (check polarity).

2.2. LCD-screen

1.

PROGRAM FOR

: Displays when programming days of week and

periods  of  day.  In  normal  state  only  current  DAY  (2)  and  single

PERIOD (3) are displayed, when in PROGRAM mode.

2.

DAY

: Current DAY of week

3.

P

E

RIOD

:

Current period of DAY

4.

MODE

: Indicates operation MODE of system

ON

(Indicates system is on, manually or thermostatically)

OFF

(Indicates system is turned off)

THERMO

(Indicates the  system  will  automatically  cycle,

depending on programmed

SET

temperature)

PROGRAM

(Indicates  the  system  is  operating  with

PROGRAMMED

settings)

5.

START AT

: Appears when programming time to turn system on

6.

SET

:

Indicates desired

SET

room temperature, when in

THERMO

or

PROGRAM

mode

7.

F°/C°

:

Temperature, in Fahrenheit or Celcius

8.

TIME/TEMP

:

Displays CURRENT room temp. In same frame, the

current time will display in AM or PM. Press

TIME/TIMER

to display current time

9.

LOW

: Battery power is

LOW

. Replace batteries within 2 weeks

10.

TIMER

: When displayed, indicates countdown timer in operation

11.

OVERRIDE

:

Displays when

SET

temperature is overridden

12.

FLAME

:

Single or double flame symbol indicates burner is operational in

LOW/HI

mode

13.

CP

:

Displays when CHILD PROOF—LOCK OUT“ is engaged. Pressing

TIME/TIMER

and

FAN

buttons together for

more than 10 seconds, engages or disengages

CP

14. (

SWING

:

not applicable)

15.

FAN

: i

ndicates the

FAN

is operating in normal speed

LOW

,

MED

or

HI

speed (when fan blade is displayed)

16.

TRANSMIT

: Lights up whenever a signal is send from the transmitter to the receiver.

3

9

2

1

5

13

8

16

12

11

14

7

4

6

10

15

Содержание RC-16B

Страница 1: ...User Guide RC 16B WELL STRALER Hertstraat 99 B 9473 Welle T 32 0 53 66 64 65 F 32 0 53 67 34 00 info wellstraler be...

Страница 2: ...ng of the current hour and minutes 6 2 4 Program operation of remote control 7 2 5 1 Programming day period of day temperature 7 2 5 2 Program overview 9 2 5 3 Program cancellation return to factory s...

Страница 3: ...as been done by an unauthorized person Delicate parts in contact with fire like glass etc are not covered by warranty Complaints are only accepted when made through a recognized dealer 1 3 Security 1...

Страница 4: ...e and the receiver will begin emitting a series of 4 beeps every 2 seconds When the ambient temperature near the receiver drops under 50 C you can reactivate the appliance by pushing MODE on the trans...

Страница 5: ...R Displays when programming days of week and periods of day In normal state only current DAY 2 and single PERIOD 3 are displayed when in PROGRAM mode 2 DAY Current DAY of week 3 PERIOD Current period...

Страница 6: ...perature C push SET RETURN after step 1 2 3 2 Setting the current day of the week DOWN FAN TIME TIMER FLAME BACK SET RETURN PROGRAM REVIEW AHEAD MODE UP 4 Following step 3 above the SU symbol will beg...

Страница 7: ...ge the built in time and temperature programs to suit your personal schedule Each day is divided into four periods MORNING DAY EVENING and NIGHT A blank programming chart is provided above to record y...

Страница 8: ...temperature 7 When the desired SET TEMP displays press PROGRAM REVIEW to confirm 8 After pressing the PROGRAM REVIEW button in step 7 the next PERIOD of the same DAY or next DAY will display on the L...

Страница 9: ...until the LCD screen displays ON Together with ON the LCD screen will display FLAME and 1 flame symbol At this point the spark electrode will begin sparking to ignite the pilot for a period of maximum...

Страница 10: ...screen Together with PROGRAM the following is displayed on the LCD screen Current period of the day morn day eve nite depending on the program ON OFF to mark if the appliance is turned on or not Room...

Страница 11: ...OVERRIDE operates only in PROGRAM mode You can change the current SET temperature without changing the programs stored in the transmitter s memory The OVERRIDE feature will be automatically cancelled...

Страница 12: ...d significantly At this time approximately two weeks of battery power remains until the transmitter may experience partial or complete loss of functions Here s how to replace the batteries 1 Push the...

Страница 13: ...odes LEARN Each transmitter can use one of the 1 048 576 security codes It may be necessary to program the remote receiver to LEARN the security code of the transmitter upon initial use if batteries a...

Страница 14: ...14...

Страница 15: ...ep The transmitter is positioned out of range of the receiver for more than 1 hour Place the transmitter closer to the receiver or move the antenna of the receiver The receiver beeps repeatedly in qui...

Отзывы: