1. Introduction
1.1. Welcome
Thank you for buying your Well Straler gas heater.
We are glad to have you as a customer. With this quality product you will enjoy the cosy warmth and unique flame dance for
many years.
Before using the heater, please read the instructions carefully and keep them in a safe place.
Installation must be carried out by a suitably qualified gas technician in accordance with the gas safety regulations that are
currently in effect. Make sure that you get informed by your technician about how to use, operate and maintain your
appliance. Every appliance has been tested, carefully adjusted and sealed in the factory in accordance with I2H or I3B/P
category. The warranty will only be valid if the service has been completed by a competent person (according the gas safety
regulations in force). Failure to install the fire correctly could lead to prosecution.
The appliance is covered with a heat-resistant surface coating. During the first few hours of use, it is absolutely normal that
a harmless temporary odor is produced. This disappears after a short period. We advise you to let the appliance work for a
few hours in a well ventilated room.
1.2. Warranty
This product has a 2 year warranty counting from the date of installation, and this for manufacturing defects only. The
warranty is limited to a simple exchange of parts that are recognized as defective by our technical department, and not
giving cause by any means to further liability. Shipping costs and labor are not part of the warranty and have to be paid by
the user. Warranty will be invalidated if the appliance has been poorly maintained, used in a wrong way, has been damaged
in an accident or catastrophe of which the origin has no connection with the appliance itself, or if service has been done by
an unauthorized person. Delicate parts in contact with fire like glass etc. are not covered by warranty. Complaints are only
accepted when made through a recognized dealer.
1.3. Security
1.3.1. Built-in safeties in the control system
The system operates on radio frequency signals that are sent by the transmitter (remote) to the receiver in the appliance.
We recommend that the transmitter always be located within the operating range (± 6 m).
To avoid unpleasant situations, the system has several built-in safety measures that alert the user when action is needed.
1.3.2. Thermo safety - transmitter
The transmitter has a thermo-safety function built into its software. It provides an extra margin of safety when the appliance
is in the
THERMO
or
PROGRAM
mode.
The thermo-safety is activated when the transmitter is moved beyond the maximum recommended operating range, which is
± 6 m. It is also activated when batteries become weak or are removed from the transmitter. The thermo-safety operates in
the following manner (only in
THERMO
or
PROGRAM
mode):
The room temperature is measured every 2 minutes by the transmitter and compared against the
SET
temperature. In
addition to check these temperatures, the transmitter sends an RF signal to the receiver, signaling that the transmitter is still
in the operating range. Should the receiver NOT receive a transmitter signal every 2 minutes, the IC software in the receiver
will begin a 45 minutes countdown timing function (thermo-safety function).
If the receiver does not receive a signal from the transmitter during this 45 minutes period, the system will shut down the
appliance. The receiver will produce a series of rapid beeps for a period of 10 seconds, followed by a single beep every 4
seconds until a transmitter signal is again received and the system is
RESET
.
To
RESET
the receiver: press the
MODE
button until
OFF
appears on the LCD-screen. It is now possible to operate the
appliance to the preferred working mode.