1.3.3. Communication safety – transmitter
The communication-safety operates in all operation modes (
ON-THERMO-PROGRAM
):
At all times and in all operating modes, the transmitter sends an RF-signal every 15 minutes to the receiver, signaling that
the transmitter is within the normal operating range of ± 6 m. Should the receiver not receive a transmitter signal, the IC-
software in the receiver will begin a 1 hour countdown timing function. If the receiver does not receive a signal from the
transmitter during this 1 hour period, the system will shut down the appliance. The receiver will produce a series of rapid
beeps for a period of 10 seconds, followed by a single beep every 4 seconds until a transmitter signal is again received and
the system is
RESET
.
To
RESET
the receiver: press the
MODE
button until
OFF
appears on the LCD-screen. It is now possible to operate the
appliance to the preferred working mode.
1.3.4. Thermo-safety – receiver
The system has a thermo-safety feature that is built into the receiver. This feature is temperature-activated and it provides
an extra margin of safety in case the receiver should be placed where ambient temperatures exceed 65°C. At 65°C the
thermistor will automatically shut down the fireplace and the receiver will begin emitting a series of 4 beeps every 2 seconds.
When the ambient temperature near the receiver drops under 50°C, you can reactivate the appliance by pushing
MODE
on
the transmitter.
1.3.5. Child Protection (CP)
The system includes a child-proof ‘lock-out’ feature that allows the user to ”lock-out
’
operation of the appliance from the
transmitter.
REMARK
: If the appliance is already operating in ON, THERMO or PROGRAM modes, engaging the ”lock-out” will not
cancel the operating mode. It only prevents the manual operation of the transmitter. If the appliance is operating in AUTO
mode (thermo and/or program operation) it will continue working normally. To totally ”lock-out” the operation of the
transmitter’s operating signals, the transmitter
’
s mode must be set to OFF.
DOWN
FAN
TIME
TIMER
FLAME
BACK
SET
RETURN
PROGRAM
REVIEW
AHEAD
-
+
MODE
UP
1. To activate the ”LOCK-OUT‘, press and hold the
TIME/TIMER
and
FAN
buttons together for
5 seconds. The letters
CP
will appear in the
TEMP
frame on the LCD-screen.
2. To disengage the ”LOCK OUT,‘ press and hold the
TIME/TIMER
and
FAN
buttons together for at least
5 seconds.
1.4. Appliances with ventilator
To prevent cold air to flow out of the cooled-down appliance, the ventilator begins working after the appliance has warmed
up (± 5 minutes warming up at the maximum rate). After extinction of the burner the ventilator keeps working for 15 minutes,
in order to use the residual warmth.