32
IOM-189
MODEL: INFLOW™ ACE MANUAL INSERTION
REV: G
13839 West Bellfort Street, Sugar Land, TX 77498
welker.com
Service Department 281.491.2331
Reassembling the Insertion Tool
24.
Lay the upper bracket standoffs with the stabilizer bar and upper bracket attached between the insertion tool shafts.
25.
Using the flat washers, lock washers, and hex nuts, secure the top brackets to the upper bracket standoffs.
26.
Using the flat washers, lock washers, and hex nuts, secure the top brackets to the insertion tool shafts.
27.
Connect the insertion tubing to the insertion tool housing caps.
28.
To continue maintenance on the inFlow™ ACE, set the insertion tool aside and continue to
3.3 Maintenance: inFlow™ ACE
1.
Prior to performing maintenance, the inFlow™ ACE must be removed from the pipeline. See
for instructions on retracting the insertion shaft and removing the unit from the pipeline.
2.
If applicable, remove the optional insertion tool prior to performing maintenance. See
for instructions on removing and maintaining the insertion tool.
3.
Relieve any trapped pressure by loosening the jam nut and turning the adjusting screw on the external sand relief
counterclockwise and opening purge valve P (
and
).
4.
Lay the inFlow™ ACE on a smooth, clean surface
Collection Head Assembly
Welker recommends noting the position of the jam nut on the outer shaft to ease reassembly.
5.
Loosen the lock collar, and then expose the collection head manually by gently pushing the collection head out of the
lubricator body.
6.
As necessary, cut the safety wire from the relief cap to the jam nut, and then remove the safety wire.
7.
Unscrew and remove the collection head assembly from the outer shaft.
8.
Refer to
Appendix B, D-Style Collection Head Maintenance,
Appendix C, C-Style Collection Head Maintenance,
for
instructions on performing maintenance on the collection head.