While under special circumstances the 4T option may be something to explore, all features including such as
upslope and
downlslope as well as starting and ending amps can be used in 2T mode
and you may find that 2T mode a much more user
friendly mode to operate in. In fact, you may never find the need for 4T at all.
Remember when using the foot control pedal,
always choose 2T and set all upslope, downslope settings to zero, and set starting and end amps to their lowest value.
•
NOTE REGARDING 4T MODE
Note
:
When switching between Trigger Button and Foot Control, it may be necessary to “reindex”
the amperage setting. This simply means to adjust and reset the amperage knob on the
face of the welder, even if the same current setting is being used in either mode.
Reindexing tells the machine to recognize the newly attached device, be it the button or
foot control.
The 4T function requires 4 Trigger button movements to start and end a weld. 1 push to start the weld, 2 release to maintain the
weld and continue, 3 push the trigger button once again as the first step to ending the weld, and finally 4, release the button to
stop the weld.