Installation diagram for TIG
TIG WELDING
Electric current flows from negative to positive. When TIG welding the polarity settings should always be
Straight Polarity
Electrode Negative.
That means that the Work clamp (aka ground) is connected to the Plus (+) Dinse connector, and not the
negative as some consider normal. When connecting the TIG Torch, a gentle snug connection is all that is needed.
DO NOT
OVER TIGHTED THE BRASS CONNECTOR.
22
•
Set up for air cooled TIG torch
Set up for water cooled TIG torch
Note
:
120V/220V COOLER OUTLET. RECOMMENDED
FOR DUAL VOLTAGE Weldpro Supercool W300
ONLY. WARNING: DO NOT USE THIS OUTLET
FOR ANY OTHER APPLICATION OR SERVICE!
Ground clamp
Work
piece
Electrode
holder