8.
PREVENTATIVE MAINTENANCE
ALL SERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN.
Refer to maintenance procedures and parts list manual for detailed
maintenance and testing instructions.
WARNING / AVERTISSEMENT / ADVERTENCIA
If for any reason this unit is not functioning correctly
DO NOT OPERATE
. Contact your autorized service agent.
!
0
DAILY
PRE-STARTUP
INSPECTION
1.
Kettle tilts smoothly, handle is tight and kettle holds in any position (tilting models only).
2. Pressure gauge is in the green when unit is cold.
3. Green light comes on when unit is energized.
4. Red light comes on when unit is tilted (tilting models only).
5. Cover is held in position by spring when raised (spring assisted covers only).
6. Cover is held securely to handle, knob is on the end of the handle.
SIX MONTH SERVICE INSPECTION
1. Perform daily startup inspection.
2. Grease bearings on both trunnions.
3. Inspect worm and gear for tightness and grease.
4. Perform pressure relief valve periodic test (see Pressure Relief Valve Testing).
5. Check that both bottom cover gaskets are
in place and are not cracked or split.
6. Check that unit is bolted in place.
7. Insure there are two screws firmly holding
down the cover. If not replace screws.
8. Check hand wheel for tightness. If loose tighten Allen screw.
9. Check spring assist hinge screws are tight (for cover).
YEARLY SERVICE INSPECTION
1.
Perform six month service inspection.
2.
Check kettle maximum temperature setting (see CALIBRATING PROCEDURE).
3.
Perform safety inspection using SAFETY INSPECITON CHECKLIST found in the MAINTENANCE PROCEDURES.