24
INSTRUCTIONS
NOTE:
Use thread sealant compatible with propane gas
on all threaded piping connections.
1.
Disconnect electrical connection.
2.
Shut off main gas supply and disconnect kettle from
supply line.
3.
Remove TOP COVER.
4.
Remove PLUG and SPRING.
5.
Remove GAS ORIFICE and “O” RING.
6.
Replace with new GAS ORIFICE and “O” RING.
7.
Replace SPRING and PLUG.
8.
Replace TOP COVER.
9.
Check inlet pressure is between 12-14 inches W.C.
10.
. Check input rate of unit.
11.
On the underside of the console cover with indelible
marker place the following information: Company,
Name, Address & Date of Conversion.
12.
Replace TOP COVER.
13.
Place gas conversion label next to rating label.
14.
Reconnect electrical and gas supplies.
Conversion Parts Required
Kit Service #KE003716-4)
Part No.
Description
Quantity
KE603911-4
Conversion Label
1
KE53403-7
Gas Orifice
1
FA05002-29
“O” Ring
1
KE603910-3
Instruction Seet
1
TOP
COVER
NATURAL GAS TO PROPANE
CONVERSION KIT
THIS CONVERSION KIT SHALL ONLY BE INSTALLED BY A
QUALIFIED SERVICE AGENCY
For use at 0-2000 feet elevation on Honeywell valves Model
8305. For higher elevations consult the factory.
PLUG
SPRING
GAS ORIFICE
“O” RING
Air Intake Washer (KE54420-1) is required for 50Hz units - see conversion kits
KE003716-6 & KE003716-7.
Unit exhaust contains carbon monoxide.
Operate only under a properly
functioning hood with adequate
makeup air.
DANGER:
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer’s
instructions and all applicable codes and requirements
of the authority having jurisdiction. If the information in
these instructions is not followed exactly, a fire, and
explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of life.
The qualified service agency is responsible for the
proper installation of this kit. The installation is not
proper and complete until the operation of the
converted appliance is checked as specified in the
manufacturer’s instructions supplied with the kit.
The gas supply shall be shut off prior to disconnecting
the electrical power, before proceeding with the
conversion.
WARNING:
CAUTION
!
!
Содержание CLEVELAND HA-MKGL-100
Страница 30: ...29 WIRING DIAGRAM 208 240V Page 1 of 2 Continued on page 2...
Страница 31: ...30 WIRING DIAGRAM 208 240V Page 2 of 2 Continued from page 1...
Страница 32: ...31 WIRING DIAGRAM 460 480V Page 1 of 2 Continued on page 2...
Страница 33: ...32 WIRING DIAGRAM 460 480V Page 2 of 2 Continued from page 1...
Страница 59: ...TILTING MODELS STATIONARY MODELS 58 PLUMBING ASSEMBLY WATER METER...