![Weishaupt WRSol 1.0 Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/weishaupt/wrsol-1-0/wrsol-1-0_manual_953375031.webp)
31
4
MFA
X1:
N
1
N
2
N
L
3
N
L
4
5
6
TSU
eBus
TKO
PS
TSU
THR
PS
M
TPU
VRA
VSP
VSP
TKO
PFK
PFK
TFK
TFK
TPO
TPO
TPU
M
M
THR
VRA
TV
AB
B
A
AB
B
A
X2:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
•
Three way valve
•
Heating return temperature increase
The WRSol 2.0 determines the temperature differential
between the collector sensor (TKO) and the reference
sensor (TSU, TPU). As soon as the temperature differential
is greater than the value (
... Diff. On
) set, the solar
pump is switched on and the storage tank is loaded.
Once the (
... Temp. Setpoint value)
has been
reached the three way valve switches over and loads the
calorifier provided, according to the priority setting
(
➭
Ch. 7.12).
Using the three way valve for return temperature increase
(VRA) the available energy from the calorifier can be
utilised depending on the calorifier temperature (TPO) and
the heating return sensor (THR).
Release of solid fuel boiler pump (PFK) (
➭
Ch. 7.7).
The thermal mixer valve (TV) enables fast heat up of the
solid fuel boiler.
Depending on the average pump speed and the minimum
storage tank temperature, the external heat exchanger can
be blocked via the potential free
Multi-funct. Output
(MFA).
In addition an 18 hour block can be activated.
The DHW function (Ch. 7.14) can also influence the MFA
output.
Possible settings MFA output:
0, 1, 2, 5, 6, 7, 8, 9, 10, 11, 12
Variation 38: Storage tank cascade for DHW and heating support with collector and solid fuel boiler
WW
KW
MFA
X1:
N
1
N
2
N
L
3
N
4
5
6
e-Bus
TKO
PS
TKR
TPU
VUP
PFK
TFK
TPO
PS
TKO
PFK
TFK
TPO
TPU
M
M
VUP
TV
AB
B
A
VIZ*
VIZ*
TKR*
X2:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
•
Energy yield calculation (optional;
➭
Ch. 7.10)
The WRSol 2.0 determines the temperature differential
between the calorifier sensor (TKO) and the reference
sensor (TPU).
As soon as the temperature differential is greater than the
value set (
Calorifier Diff. On
), the solar pump is
switched on and the storage tank is topped up until the
switch off condition (
Calorifier Temp. Off
) or the
maximum calorifier temperature has been reached.
Release of solid fuel boiler pump (PFK) (
➭
Ch. 7.7).
Switch over three way valve (VUP) (
➭
Ch. 7.22)
The thermal mixer valve (TV) enables fast heat up of the
solid fuel boiler.
The external heat exchanger can be blocked via the
potential free
Multi-funct. output
(MFA).
Possible settings MFA output:
0, 5, 6, 7, 8, 9, 10, 11, 12
Variation 40: Calorifier for heating with collector and solid fuel boiler
* optional