Note: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own expense.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
16.215.2
Hazardous Location Compliance
The MPM, RSP, and power supply are certified to meet the following hazardous location
standards and gas groups
o
Class I Division 2, Groups B,C,D T3
o
Class I Zone 2, AEx nA IIB+H2 T3
o
Ex II 3GD EEx nA IIB+H2 T3 Dc
Canada / US Hazardous Location Compliance
o
ANSI/ISA 12.12.01: Nonincendive Electrical Equipment for Use in Class I and
II, Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) Locations
o
CAN/CSA C22.2 No. 213: Non-Incendive Electrical Equipment for Use in
Class I, Division 2 Hazardous Locations
European / International Hazardous Location Compliance
o
EN 60079-0, IEC 60079-1 : Electrical Apparatus for Explosive Gas
Atmospheres Part 0: General Requirements
o
EN 60079-15, IEC 60079-15 : Electrical Apparatus for Explosive Gas
Atmospheres Part 15: Electrical Apparatus with Type of Protection "n"
MPM IECEx certificate no: IECEx EMT 17.0018X
MPM ATEX certificate no: EMT17ATEX0043X
RSP certificate no: EMT17ATEX0044X
The sensors chosen to be used by this system will need to be certified to the hazardous
location compliance directives applicable to the country where the installation takes place.
External devices like a QPro radio and external model are not covered in a hazardous
location and will need to be placed outside of the hazardous location area. All connections
within a hazardous location area will need to have the locking connectors installed in order to
prevent accidental disconnection of these connectors.