Electrical connection and safety measures through handling with
electrical energy:
-
The electrical connection of the high pressure system must be carried out by a qualified
electrician and comply with IEC 364
-
On site, in the electrical system , must installed either a fault-current circuit breaker, which
interrupt the main voltage when the fault current exceeds 30mA during 30ms or mount an
earth tester
-
Work at the electrical installation of the system may only be carried out by a qualified
technician
-
The voltage indicated on the type plate must comply with the voltage of the power source
-
The power supply must be fused according to system type / type plate or our allowance.
-
A higher fuse is not allowed
-
Electrical connection and network main fuse to be installed only by a professional
-
The system must be correctly installed according to instructions of VDE and EVU at socket /
distribution.
-
Connect the system only to a proper power source
-
Check the plug, respectively supply cable for damage
-
Do not connect a damaged cable
-
For replacement or renewal of the supply cable only the original supply cable of the
manufacturer must be used, order number see spare parts list
-
Electrical connections must be clean as well as dry and should not lie on the floor
-
Do not touch the plug with wet hands
-
By using an extension cable, the plug and coupling must be made of a waterproof construction
-
Unsuitable extension cables can lead to death