38
IMPORTANT! Check the LED- display
Malfunction and remedy
Error:
Possible cause:
Remedy:
High manometer amplitude by closing
the trigger gun
Operating pressure is very low / minor
Operating pressure is high
Detergent do not become sucked
( only by detergent injector )
Heater is not coming at temperature
Blower motor is not running
Ignition is not carried out
Fuel atomisation insufficient
No / very low oil pressure
Fuel solenoid valve opens
Safety valve incorrectly set or defect
Pressure regulating valve switches
incorrectly
Wrong nozzle size
Heizschlange verkalkt
Pressure regulating valve wrong
adjusted
Pressure regulating valve is leaky
Pressure gauge is defect
Pressure regulating valve is defect
High pressure nozzle is blocked
Detergen tank is empty
Dosing valve is closed
Detergent lines are blocked
Water flow rate is low
Pressure adjustment nozzle unclosed
Fuel tank is empty
Fuel filter is blocked
Heating coil is calcified
Combustion chamber is sooted
Blower motor is defect
Current cut-out has been released
from the blower motor
Ignition cable, ignition elctrodes,
electric plug or ignition transformer
defect
Burner nozzle is closed
Oil pressure is very low
Fuel pump / PVC-coupling defect
Fuel filter blocked or leaky
Temperaturregulator very low setted
Water flow rate very low
Flow controller / Pressure switch
defect
Fuel tank empty
Set the safety valve on max.10% over
the max. operating pressure
respectively renew
Check the function of the pressure
regulating valve respectively renew
Use nozzle as per Type label
Descale it
SetAdjust the pressure regulating
valve at the desired pressure
Repair the pressure regulating valve
Renew it
Renew it
Clean nozzle
Fill up the tank
Open dosing valve
Clean the detergent lines
Set the pressure regulator higher
Open the adjustment nozzle
Fill up the fuel tank
Clean the fuel filter, renew the fuel
pump
Descale the heating coil
Clean the combustion chamber
Renew the fuse
Set ignition electrodes according to
drawing, renew the defective parts
Clean the burner nozzle
Set the oil pressure on approx.8,5 bar
Renew
Clean, respectively seal it
Set the temperature regulator higher
Clean nozzle, increase the pressure
Exchange / Renew
Fill up fuel