User Manual Managed Switches
101
InOctets: The total number of octets received on the
interface, including framing characters.
InUcastPkts: The number of uni-cast packets
delivered to a higher-layer protocol.
InNUcastPkts: The number of broad-cast and
multi-cast packets delivered to a higher-layer
protocol.
InDiscards: The number of inbound packets that are
discarded even the packets are normal.
InErrors: The number of inbound packets that
contained errors preventing them from being
deliverable to a higher-layer protocol.
InUnknownProtos: the number of the inbound
packets that were discarded because of the unknown
or un-support protocol.
OutOctets: The number of octets transmitted out of
the interface , including framing characters.
OutUcastPkts: The number of uni-cast packets that
request to transmit.
OutNUcastPkts: The number of broad-cast and
multi-cast packets that request to transmit.
OutDiscards: The number of outbound packets that
are discarded even the packets are normal.
OutErrors: The number of outbound packets that
could not be transmitted because of errors.
OutQLen: The length of the output packet queue (in
packets).
Sample Type
Setting
Description
Factory
Default
Delta / Absolute
The method of sampling the selected variable and
calculating the value to be compared against the
thresholds.
Absolute: Get the sample directly.
Delta: Calculate the difference between samples.
Delta
Value
Setting
Description
Factory
Default
Information only
The value of the statistic during the last sampling
period.
None
Startup Alarm
Setting
Description
Factory
Default
Rising / Falling /
Rising Or Falling
The activation of the alarm.
Rising when the first value is larger than the rising
threshold.
Falling when the first value is lower than the falling
threshold.
Rising Or
Falling