User Manual Managed Switches
100
Data Source
Setting
Description
Factory
Default
Number (OID)
Indicates the port ID which wants to be monitored.
The value of the switch must add 1000000*(switch
ID-1). For example, if we want to monitor switch 3
port 5, the value is 2000005.
None
Interval
Setting
Description
Factory
Default
Time between 1
and 3600 sec
Indicates the interval in seconds for sampling the
history statistics data.
1800
Buckets
Setting
Description
Factory
Default
Numeric value
between 1 and
3600
Indicates the maximum data entries associated this
History control entry stored in RMON.
50
3.9.3 RMON Alarm Configuration
The user can configure RMON Alarm table on this page.
Press the button
Add New Entry
to create a new entry to define RMON alarms.
ID
Setting
Description
Factory
Default
Numeric value
between 1 and
65535
Indicates the index of the entry.
None
Interval
Setting
Description
Factory
Default
Time between 1
and 2
31
-1 (sec)
Indicates the interval in seconds for sampling and
comparing the rising and falling threshold.
30
Variable
Setting
Description
Factory
Default
Number (OID)
Indicates the particular variable to be sampled, the
possible variables are:
None