User Manual Managed Switches
157
IP/Ethernet Length
Setting
Description
Factory
Default
Any / 0 / 1
Specify whether frames can hit the action according to
their ARP/RARP hardware address length (HLN) and
protocol address length (PLN) settings.
Any: Any value is allowed.
0: ARP/RARP frames where the HLN is not equal to
Ethernet (0x06) or the (PLN) is not equal to IPv4
(0x04).
1: ARP/RARP frames where the HLN is equal to
Ethernet (0x06) and the (PLN) is equal to IPv4 (0x04).
Any
IP
Setting
Description
Factory
Default
Any / 0 / 1
Specify whether frames can hit the action according to
their ARP/RARP hardware address space (HRD)
settings.
Any: Any value is allowed.
0: ARP/RARP frames where the HLD is not equal to
Ethernet (1).
1: ARP/RARP frames where the HLD is equal to
Ethernet (1)
Any
Ethernet
Setting
Description
Factory
Default
Any / 0 / 1
Specify whether frames can hit the action according to
their ARP/RARP protocol address space (PRO)
settings.
Any: Any value is allowed.
0: ARP/RARP frames where the PRO is not equal to
IP (0x800).
1: ARP/RARP frames where the PRO is equal to IP
(0x800).
Any
IPv4 parameters
If the type of frame selected is
IPv4
, several additional parameters can be programmed:
IP Protocol Filter
Setting
Description
Factory
Default
Any / ICMP / UDP
/ TCP
Specify the IPv4 protocol filter for this specific ACE.
Any: No IPv4 protocol is specified.
ICMP: IPv4 ICMP protocol frames.
UDP: IPv4 UDP protocol frames.
TCP: IPv4 TCP protocol frames.
New fields are shown for the specific IPv4 protocols.
At the end of this section the new fields are described.