User Manual Managed Switches
22
User Name
Setting
Description
Factory
Default
Max. 31
characters
Enter the new user name. The valid user name is a
combination of letters, numbers and underscores.
None
Password
Setting
Description
Factory
Default
Max. 31
characters
Enter the password of the new user. Any printable
characters including space are acceptable.
None
Password (again)
Setting
Description
Factory
Default
Max. 31
characters
Enter the new password of the new user again to
confirm.
None
Privilege Level
Setting
Description
Factory
Default
0 to 15
The privilege level of the new user. The allowed range
is 0 to 15. If the privilege level value is 15, it can
access all groups, i.e. that is granted the fully control
of the device. But other values need to refer to each
group privilege level. User's privilege should be the
same or greater than the group privilege level to have
the access of that group. By default, the group
privilege level of 5 has the read-only access and the
privilege level of 10 has the read-write access. System
maintenance (software upload, factory defaults, etc.)
requires the user privilege level of 15. Generally, the
privilege level of 15 can be used for an administrator
account, privilege level 10 for a standard user account
and privilege level 5 for a guest account.
0
3.3.5.2 Privilege Levels
This page provides an overview of the default privilege levels required to perform specific actions in
the switch. It also allows the administrator to modify these default values.