Wi-Fi device IE-WL-BL-AP-CL
Getting Started
2-9
Protocol Support
General Protocols:
Proxy ARP, DNS, HTTP, HTTPS, IP, ICMP, SNTP, TCP, UDP, RADIUS, SNMP, DHCP, LLDP
Interface
Default Antennas:
2 dual-band omni-directional antennas, 2 dBi, RP-SMA (male)
Connector for External Antennas:
RP-SMA (female)
LAN Ports:
1, RJ45, 10/100/1000BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection
Console Port:
RS-232 (RJ45-type)
Reset:
Present
LED Indicators:
PWR, FAULT, STATE, SIGNAL*, WLAN, 10/100/1000 (RJ45 port)
*signal strength indicator
Physical Characteristics
Housing:
Metal, IP30 protection
Weight:
307 g (0.68 lb)
Dimensions:
58 x 115 x 70 mm (2.29 x 4.53 x 2.76 in)
Installation:
DIN-rail mounting (standard), wall mounting (optional)
Environmental Limits
Operating Temperature:
•
Standard Models: 0 to 60°C (32 to 140°F)
•
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature:
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity:
5% to 95% (non-condensing)
Power Requirements
Input Voltage:
12 to 48 VDC, redundant dual DC power inputs
Connector:
4-pin removable terminal block, 500 V insulation
Power Consumption:
6.96 W
Reverse Polarity Protection:
Present
Standards and Certifications
Safety:
UL 60950-1, EN 60950-1
EMC:
EN 55032/55024
EMS:
•
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
•
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
•
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV
•
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV
•
IEC 61000-4-6 CS: 3 V
•
IEC 61000-4-8
Radio:
EN 301 489-1/17, EN 300 328, EN 301 893, TELEC, FCC ID SLE-WAPN008, KC, RCM, ANATEL, WPC, SRRC, IC ID,
ICASA, FAC
Note: Please check Weidmüller
’s website for the most up
-to-date certification status.
Reliability
MTBF (mean time between failures)
Time:
810,022 hrs
Standard:
Telcordia SR332
Warranty
Warranty Period:
5 years
ATTENTION
•
The IE-WL-BL-AP-CL is NOT a portable mobile device and should be located at least 20 cm away from the
human body.
•
The IE-WL-BL-AP-CL is NOT designed for the general public. A well-trained technician should be enlisted