Wi-Fi device IE-WL-BL-AP-CL
Web Console Configuration
3-45
Syslog server 1/ 2/ 3
Setting
Description
Factory Default
IP address
Enter the IP address of the 1st/ 2nd/ 3rd Syslog Server
None
Syslog port
Setting
Description
Factory Default
Port destination
(1 to 65535)
Enter the UDP port of the corresponding Syslog server
514
NOTE
RSSI report events (Only for Client mode)
event type
is useful for the site survey stage. However, this
function increases the traffic load because it needs to use a special utility to retrieve the RSSI values in a
tabular format. So, we recommend disabling this function during normal usage.
E-mail Notifications
Notification Event Types
Check the
Active
box next to the event type to enable the event type for email notification. By default, all event
types are deactivated (unchecked).
E-mail Server Settings
You can set up to 4 e-mail addresses to receive alarm emails from the IE-WL-BL-AP-CL. The following
parameters can be configured on the
E-mail Server Settings
page. In addition, a
Send Test Mail
button can
be used to test whether the Mail server and e-mail addresses work well. More detailed explanations about these
parameters are given after the following figure.
Mail server (SMTP)
Setting
Description
Factory Default
IP address
The IP Address of your email server.
None