background image

10 

 

PoE 10/100BaseT(X) Ethernet Port Connection  

 
PoE 10/100BaseT(X) ports 

located on the switch’s front panel are used 

to connect to PoE-

enabled devices. The pinout follows the “Alternative 

A, MDI-

X mode” of 802.3af/at standards. Please see the details in the 

following table. 
 

PoE Port Pinout 

8-pin RJ45 

 

 

Pin 

Data 

Power 

Tx+ 

V- 

Tx- 

V- 

Rx+ 

V+ 

Rx- 

V+ 

 

 
 
 

NOTE 

According to IEEE 802.3af/at standards, the PD shall be 
implemented to be insensitive to the polarity of the power 
supply and shall be able to operate per MDI mode and MDI-X 
mode. However, some PDs only support MDI mode or MDI-X 
mode only. The following figure shows how to select the correct 
cable between the PD and IE-SW-BL06-4PoE switch. 

 

 

 

RJ45 (8-pin) to RJ45 (8-pin) Straight-Through Cable Wiring 

 

RJ45 (8-pin) to RJ45 (8-pin) Cross-Over Cable Wiring 

 

 

NOTE 

If the PD only supports MDI mode (V+, V+, V-, V- for pins 1, 2, 
3, 6), choose a cross-over Ethernet cable to connect the PD and 
the switch. If the PD only supports MDI-X mode (V-, V-, V+, V+ 
for pins 1, 2, 3, 6), choose a straight-through Ethernet cable 
between the PD and the IE-SW-BL06-4PoE switch. 

Содержание IE-SW-BL06-1TX-4PoE-1SC

Страница 1: ...product information can be downloaded using following link http www weidmueller com Select Product Catalogue Select Industrial Ethernet active Select PoE unmanaged Switches Select Product model Click...

Страница 2: ...be easily installed on a DIN Rail or in distribution boxes The DIN Rail mounting capability and IP30 metal housing with LED indicators make the switch reliable and easy to use Package Checklist Your...

Страница 3: ...ew 2 Terminal block for power input P1 P2 3 Heat dissipation orifices 4 DIP switches 5 Power input P1 LED 6 Power input P2 LED 7 PoE LED 8 10 100BaseT X port 9 TP port s 10 100 Mbps LED 10 Article Num...

Страница 4: ...E 1ST Front Panel View 1 Grounding screw 2 Terminal block for power input P1 P2 3 Heat dissipation orifices 4 DIP switches 5 Power input P1 LED 6 Power input P2 LED 7 PoE LED 8 10 100BaseT X port 9 TP...

Страница 5: ...ont Panel View 1 Grounding screw 2 Terminal block for power input P1 P2 3 Heat dissipation orifices 4 DIP switches 5 Power input P1 LED 6 Power input P2 LED 7 PoE LED 8 10 100BaseT X port 9 TP port s...

Страница 6: ...f you need to reattach the DIN Rail attachment plate make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the top of the DIN Rail into the slot just...

Страница 7: ...he screws should be less than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure at the right NOTE Before tightening the screws into the wall make sure the...

Страница 8: ...ice wiring paths must cross make sure the wires are perpendicular at the intersection point NOTE Do not run signal or communications wiring and power wiring in the same wire conduit To avoid interfere...

Страница 9: ...hernet Switch top panel ATTENTION Before connecting the Ethernet Switch to the DC power inputs make sure the DC power source voltage is stable Communication Connections The IE SW BL06 series has 4 5 o...

Страница 10: ...the polarity of the power supply and shall be able to operate per MDI mode and MDI X mode However some PDs only support MDI mode or MDI X mode only The following figure shows how to select the correct...

Страница 11: ...t of device I to the Tx transmit port of device II SC Port Pinouts ST Port Pinouts ATTENTION This is a Class 1 Laser LED product To avoid causing serious damage to your eyes do not stare directly into...

Страница 12: ...f TP Port s 10 Mbps link is inactive GREE N On TP port s 100 Mbps link is active Blinking Data is being transmitted at 100 Mbps Off TP Port s 100 Mbps link is inactive 100M GREEN On FX port s 100 Mbps...

Страница 13: ...suitable for use with large networks The address tables are self learning so that as nodes are added or removed or moved from one segment to another the Ethernet Switch automatically keeps up with new...

Страница 14: ...ode Wavelength 1300 nm Max TX 10 dBm Min TX 20 dBm RX Sensitivity 32 dBm Link Budget 12 dB Typical Distance 5 km a 4 km b Saturation 6 dBm a using 50 125 m 800 MHz km cable b using 62 5 125 m 500 MHz...

Страница 15: ...40 to 75 C 40 to 167 F Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Regulatory Approvals EMI FCC Part 15 CISPR EN55022 class A EMS EN61000 4 2 ESD Level...

Страница 16: ...n Weidm ller gives no warranty or guarantee as to the interoperability in specific systems or as to the fitness for any particular purpose To the extent permitted by law any claims for damages and rei...

Отзывы: