background image

16 

 

 
 
 
 
 
 
 
 

Weidmüller gives a 5 year warranty on this product in accordance with 
the warranty terms as described in the general conditions of sale of the 
Weidmüller company which has sold the products to you. Weidmüller 
warrants to you that such products the defects of which have already 
existed at the time when the risk passed will be repaired by Weidmüller 
free of charge or that Weidmüller will provide a new, functionally 
equivalent product to replace the defective one. Safe where expressly 
described otherwise in writing in this catalogue/product description, 
Weidmüller gives no warranty or guarantee as to the interoperability in 
specific systems or as to the fitness for any particular purpose. To the 
extent permitted by law, any claims for damages and reimbursement of 
expenses, based on whatever legal reason, including contract or tort, 
shall be excluded. Where not expressly stated otherwise in this 
warranty, the general conditions of purchase and the expressive liability 
commitments therein of the respective Weidmüller company which has 
sold the products to you shall be applicable. 
 
 
 
 
 
 
 
 

 
 

Contact Information 

 

Weidmüller Interface GmbH & Co. KG 

Postfach 3030 

32760 Detmold 

Klingenbergstraße 16 

32758 Detmold 

Germany 

 

Phone +49 (0) 5231 14-0 

Fax +49 (0) 5231 14-292083 

E-Mail [email protected] 

Internet www.weidmueller.com 

 
 

Содержание IE-SW-BL06-1TX-4PoE-1SC

Страница 1: ...product information can be downloaded using following link http www weidmueller com Select Product Catalogue Select Industrial Ethernet active Select PoE unmanaged Switches Select Product model Click...

Страница 2: ...be easily installed on a DIN Rail or in distribution boxes The DIN Rail mounting capability and IP30 metal housing with LED indicators make the switch reliable and easy to use Package Checklist Your...

Страница 3: ...ew 2 Terminal block for power input P1 P2 3 Heat dissipation orifices 4 DIP switches 5 Power input P1 LED 6 Power input P2 LED 7 PoE LED 8 10 100BaseT X port 9 TP port s 10 100 Mbps LED 10 Article Num...

Страница 4: ...E 1ST Front Panel View 1 Grounding screw 2 Terminal block for power input P1 P2 3 Heat dissipation orifices 4 DIP switches 5 Power input P1 LED 6 Power input P2 LED 7 PoE LED 8 10 100BaseT X port 9 TP...

Страница 5: ...ont Panel View 1 Grounding screw 2 Terminal block for power input P1 P2 3 Heat dissipation orifices 4 DIP switches 5 Power input P1 LED 6 Power input P2 LED 7 PoE LED 8 10 100BaseT X port 9 TP port s...

Страница 6: ...f you need to reattach the DIN Rail attachment plate make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the top of the DIN Rail into the slot just...

Страница 7: ...he screws should be less than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure at the right NOTE Before tightening the screws into the wall make sure the...

Страница 8: ...ice wiring paths must cross make sure the wires are perpendicular at the intersection point NOTE Do not run signal or communications wiring and power wiring in the same wire conduit To avoid interfere...

Страница 9: ...hernet Switch top panel ATTENTION Before connecting the Ethernet Switch to the DC power inputs make sure the DC power source voltage is stable Communication Connections The IE SW BL06 series has 4 5 o...

Страница 10: ...the polarity of the power supply and shall be able to operate per MDI mode and MDI X mode However some PDs only support MDI mode or MDI X mode only The following figure shows how to select the correct...

Страница 11: ...t of device I to the Tx transmit port of device II SC Port Pinouts ST Port Pinouts ATTENTION This is a Class 1 Laser LED product To avoid causing serious damage to your eyes do not stare directly into...

Страница 12: ...f TP Port s 10 Mbps link is inactive GREE N On TP port s 100 Mbps link is active Blinking Data is being transmitted at 100 Mbps Off TP Port s 100 Mbps link is inactive 100M GREEN On FX port s 100 Mbps...

Страница 13: ...suitable for use with large networks The address tables are self learning so that as nodes are added or removed or moved from one segment to another the Ethernet Switch automatically keeps up with new...

Страница 14: ...ode Wavelength 1300 nm Max TX 10 dBm Min TX 20 dBm RX Sensitivity 32 dBm Link Budget 12 dB Typical Distance 5 km a 4 km b Saturation 6 dBm a using 50 125 m 800 MHz km cable b using 62 5 125 m 500 MHz...

Страница 15: ...40 to 75 C 40 to 167 F Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Regulatory Approvals EMI FCC Part 15 CISPR EN55022 class A EMS EN61000 4 2 ESD Level...

Страница 16: ...n Weidm ller gives no warranty or guarantee as to the interoperability in specific systems or as to the fitness for any particular purpose To the extent permitted by law any claims for damages and rei...