43
<Note>
If IP camera is connected to PoE port, user should do as follows to connect the webpage of that IP camera.
1.
Connect LAN cable of PC or notebook PC with one of NVR’s PoE port.
2.
Set the IP address of PC (or notebook PC). IP address should be in the same subnet with IP Address2 (PoE) of
NVR. (ex: If IP Address2 (PoE) is 192.168.110.5 and Net Mask2 is 255.255.255.0, then IP address of PC (or notebook
PC) should be set 192.168.110.xxx and subnet mask should be 255.255.255.0.)
3.
Connect to the webpage of IP camera connected to NVR’s PoE port using PC’s web browser.
Gateway
NVR should have proper Gateway address to communicate with external network. This information should
be given from the network administrator. (When DHCP is enabled, this item will be disabled)
Gateway setting is for NVR’s LAN (or LAN1 of 64 CHANNEL NVR).
DNS
NVR should have proper DNS address to use various network services such as WRS, NTP, e-mail and so on.
Please ask this information to network administrator.
UPnP Port Forwarding
When using router supporting UpnP, NVRs which are connected to that router can be accessed through
external internet by using automatic port forwarding feature of UPnP.
Set [Port Forwading] as ON, then [Status] will show the status of port forwarding. If ‘Port mapping is OK’,
user can access NVR through external internet by using [External IP Address].
(UPnP of router must be ON. Please refer the router’s manual to set UPnP.)
Port
Register port # in NVR and use it to connect to control center or webviewer.
<Notice>
Default port is 80 and be careful in entering the port # when used with PPPoE modem and router. To use port
forwarding & UPnP port forwarding, network port change (e.g. 8000) might be necessary. Please ask this
information to network administrator.
Bandwidth limitation.
Bandwidth is to configure the maximum transmission speed. Its default value is unlimited and users don’t
have to set bandwidth value if there is no need to limit the network data size of NVR
.
<Warning>
Please consult NVR manager if you want to modify bandwidth value.
Default Network Value
DHCP: OFF
IP Address: 192.168.0.2
Subnet mask: 255.255.255.0
Gateway: 192.168.0.1
Содержание UHN Series
Страница 1: ...1 HD CCTV NVR Digital Video Recorder UHN Series User s Manual EN Rev 1 0...
Страница 16: ...16 HDD installation 16 CHANNEL NVR 36 CHANNEL PoE NVR...
Страница 17: ...17 64 CHANNEL NVR...
Страница 18: ...18 64 CHANNEL Hot Swap NVR...
Страница 86: ...86 Product Dimension 16 CHANNEL NVR 36 CHANNEL NVR...
Страница 87: ...87 64 CHANNEL NVR 64 CHANNEL HOT SWAP NVR...