13 | Initial Operation
39
2 Has muffler and exhaust tube been routed a safe distance from
flammable material?
3 Ensure drain-holes are drilled in low bend areas of exhaust tube.
4 Ensure exhaust is venting a safe distance from any vehicle interior
openings.
5 Ensure exhaust is venting in the direction that will not cause back
pressure while driving.
Combustion Air Intake
Complete
(Yes/No/Comments)
1 Is the combustion air intake drawing fresh air from a non-turbulent
location? (i.e. not in direction of travel)
2 Ensure the air intake system is securely fastened.
Heater Function
Complete
(Yes/No/Comments)
1 Ensure the heater starts and runs for a minimum of 20 minutes.
2 Ensure vehicle blower operates as intended.
3 Ensure warm air is blown out of interior vents after blower is activ-
ated.
4 Ensure timer (control element) is functioning.
5 Check and Modify CO2 setting as needed based on allowable alti-
tude limits.
(See service manual for instructions to make adjustment)
Cosmetics
Complete
(Yes/No/Comments)
1 Has the vehicle interior, engine compartment, & glove compart-
ment been inspected for cleanliness after installation.
2 Has the user manual been placed in the glove box?
3 Is the vehicle clock time correct after disconnecting the battery?